Ambient and Operating Conditions (HCS, HMV, HMS, HMD, HCQ, HCT,
KCU, HLC)
Description
Symbol
Unit
Value
Conductive dirt contamination
Not allowed
Protected the devices against conductive dirt con‐
tamination by mounting them in control cabinets of
the degree of protection IP54 (in accordance with
IEC 60529).
Degree of protection of the device (IEC 60529)
IP20
Use in the scope of CSA / UL
For use in NFPA 79 Applications only.
Temperature during storage
See
chapter 5.2.2 "Storage of the Components" on
Temperature during transport
chapter 5.2.1 "Transport of the Components" on
Allowed mounting position
Definition of mounting positions: See
"Mounting Positions of Components" on page
G1
Installation altitude
h
nenn
m
1000
Ambient temperature range
T
a_work
°C
0 … 40
Derating vs. ambient temperature:
In the ambient temperature range T
a_work_red
, the
performance data are reduced by the factor F
Ta
:
F
Ta
= 1 - [(T
a
- 40) × f
Ta
]
For the drive connection box KCU, the rated
power (P
out
) is reduced at the output of the 42 V
control voltage. The rated power at the output of
the power section (P
DC_cont
) is not reduced.
Example: With an ambient temperature
T
a
= 50 °C and a capacity utilization factor
f
Ta
= 2
%/K, the rated power is reduced to
P
DC_cont_red
= P
DC_cont
× F
Ta
=
P
DC_cont
× (1 - [(50 - 40) × 0.02]) = P
DC_cont
× 0.8
Operation at ambient temperatures outside of
T
a_work
and T
a_work_red
is not allowed!
T
a_work_red
°C
40 … 55
f
Ta
%/K
2,0
Exception HMV02.1R-W0015-A-07-NNNN:
2,7
DOK-INDRV*-SYSTEM*****-PR06-EN-P
Rexroth IndraDrive Drive Systems with HMV01/02 HMS01/02, HMD01, HCS02/03
Bosch Rexroth AG
59/309
General Data and Specifications