Take value C
DCext
into account when operating HLC01!
Observe the different abilities which HMV supply units and HCS
converters have to charge external capacitances at the DC bus (L
+, L-).
Take the value C
DCext
into account which is contained in the tech‐
nical data of the respective device.
See also Project Planning Manual "Rexroth IndraDrive Supply
Units and Power Sections" → "HCS03 Power Sections" → "Techni‐
cal Data" → "Basic Data" → Data of Power Section - DC bus
In the HCS03 product series, it is only allowed to operate external
capacitances at the DC bus for the HCS03.1E-W0210 type.
Allowed Combinations
The table below shows which additional components are allowed at the DC
bus of HMV supply units and HCS converters.
Project planning of HLC
Take the charging ability C
DC_ext
of the used supply unit or con‐
verter into account.
Supply unit or converter
HLB01.1C
HLB01.1D
HLC01.1C
HLC01.1D
HLR01.1
HLL02.1
HMV01.1E-W
-
■
≤ 2
■
2)
■
-
-
HMV01.1R-W
-
■
2)
■
-
-
HMV02.1R-W
■
≤ 2
-
■
-
-
-
HCS02.1
■
■
2)
■
■
2)
■
3)
-
HCS03.1
■
2)
■
-
■
1)
■
4)
-
■
Allowed
■ (!)
Must be used
-
Not allowed
1)
Only HCS03.1E-…-W0210
2)
Different mounting depths: Control cabinet adapter HAS03 required
3)
HCS02.1E-W0054, -W0070 (standard equipment: braking transistor
integrated)
4)
HCS03.1E in optional design -xxBx (integrated braking transistor) re‐
quired
Tab.8-14:
Combinations With Additional Components