49
ENGLISH
GB
Code
Causes
Solutions
HIGH
TEMPERATURE
HACCP temperature alarm.
The temperature measured by the room probe
has exceeded the limit imposed by its
parameters.
Verify the cell temperature
LOW
TEMPERATURE
CYCLE
DURATION
Duration of Blast Chilling
The blast chilling / freezing cycle ended beyond
the maximum duration allowed (HCCP alarm)
Check the product quantity inside
the blast chiller.
BOARDS
COMMUNICATIONS
Interface communication error user- control
module.
Contact the after-sales
service.
BOARD
COMPATIBILITY
Interface compatibility error user- control
module.
Contact the after-sales
service.
NEEDLE
PROBE
Core probe alarm (all enabled core probe
sensors are in alarm)
Contact the after-sales
service.
POWER
FAILURE
Power failure alarm (HACCP alarm).
Verify the connection device -
electrical power supply
NEEDLE PRB INS
FISH SAN.
Product probe insertion alarm during the fish
sanitizing cycle.
Verify the proper insertion of the
core probe
SANITIZATION
DURATION
The fish sanitizing cycle has concluded beyond
the maximum duration allowed (HCCP alarm)
Verify the proper insertion of the
core probe
NEEDLE PROBE
INS.
Product probe insertion alarm during a blast
chilling / freezing cycle.
Verify the proper insertion of the
core probe