9
ENGLISH
GB
Positive Temperature Blast Chilling
This cycle lowers the temperature at the
core of the product from
+ 90 ° C
to
+ 3 ° C
in the
shortest time possible and within a maximum time
of
90 minutes
. The end of the cycle is determined
by the achievement of the value
+ 3 ° C
read by
the core probe.
Selecting the positive blast chilling cycle, the
system displays following screenshot :
By default the system suggests the temperature
cycle.
Pressing the area
it is
possible to change the operating cell temperature.
Following screenshot appears :
By pressing the
and
area the
temperature value can be changed.
To confirm the new value, press the
area;
To cancel the change press the area
.
To exit without saving press the area
.
Pressing the area
it is
possible to change the product temperature at the
end of the cycle.
Pressing the area
it is
possible to change the fan speed during the blast
chilling.
Pressing the area
it is possible to change
the cell temperature and the speed of the fans
during the conservation phase :
Press the area
to enable the intensive
phase: the relative area will be enlightened
.
In this case the positive chilling cycle will be
divided into three stages :
Intensive blast chilling (HARD)
standard blast chilling
conservation
Pressing the
area, the controller displays
the “advanced setting” screen :
Within this mode, following values can be
changed :
cell temperature
during the intensive phase ;
product
temperature at the end of intensive cycle ;
cell temperature
during the conservation phase ;