17
ENGLISH
GB
Continuous Timed Cycle
This cycle can be used when large
quantities of food are to be chilled and the specific
chilling time of each product is known. Just set the
cell temperature, the fan speed and start the
machine. The appliance maintains the set
temperature, the defrosting is automatically
managed. The cell temperature can be changed
during the normal operation.
By selecting the continuous timed cycle the
system will propose following screenshot :
By pressing the area
it is
possible to change the operating cell temperature.
By pressing the area
it is
possible to change the fan speed.
To confirm the new settings press the
area
on the right bottom : the cycle will start.
During a current cycle, following screenshot will
be displayed :
The cycle starts only by activating the first timer; it
is possible to set up to three different timers.
Timers can be set by pressing the pencil area and
setting the time while the cycle is running.
When setting the time, once the timer is
confirmed, its count starts directly.
Each timer is independent and can be reset at its
completion.
The cycle ends when all set timers have expired.
At the end of a timer count, the buzzer sounds,
the display shows a message and the value “0
min “of the corresponding timer is displayed in
green.
Pressing on the area
the display show the
temperatures detected by the various probes, the
state of inputs / outputs and the alarms stored by
the system. To abort the current cycle press for at
least three seconds the area
.
Number of the current phase
Time from cycle begin