10
ENGLISH
GB
fun speed during the
intensive phase ;
fun speed during the
conservation.
To exit the “advanced settings” screen press
on the upper left display area.
To confirm the blast chilling cycle settings press
the right lower area
.
If a standard chilling cycle has been selected,
following screenshot will appear:
If an intensive chilling cycle (HARD) has been
selected, following screenshot will appear:
To change the values within the single phases,
press in the area involved.
E.g. to change the temperature of the cell during
the intensive phase, press in correspondence of
phase 1; the screen of the first phase will be
showed.
To save and store the set cycle press in
correspondence of the area
. To start the
cycle press in correspondence of the area
.
During a current cycle, following screenshot will
be displayed :
Pressing on the area
the display show the
temperatures detected by the various probes, the
state of inputs / outputs and the alarms stored by
the system. To abort the current cycle, press for at
least three seconds the area
.
Number of the current phase
Time left
Positive blast chilling symbol
Intensive blast chilling symbol
Temperature cycle symbol