5.8 The ventilator during ventilation
Monitoring ventilation
The curves screen appears as soon as ventilation is started:
You can monitor ventilation continuously using the following tools on the curves screen:
•
The bar graph
•
The pressure and flow curves
•
The instantaneous measurements for certain parameters
•
The
symbol which appears below the bar graph to indicate a triggered cycle.
Selecting the four displayed measurements
Modifying the appearance of the curves
You can change the appearance of the pressure and flow curves (filled or outline) as follows:
ACV
ACV
info
HP
HP
0
10
20
30
40
50
60
70
80
90
23
cm
H2O
P
peak
peak
20,3
cm
H
2
O
FiO
FiO
2
21
%
M
od
es
Pa
ra
m
<PE
<PE
P
16
0
28
0
>
>
v
O
2
100%
2
min
O
2
consumed:
consumed:
- - l/min
- - l/min
Freeze-> Touch curves
V
Ti
Ti
501
ml
V
Te
Te
503
ml
1/4
Instantaneous
measurements
Current mode
Press to change
the mode
Press to adjust
parameter settings
Press to access
alarm settings
Press to access respiratory
mechanics parameters
Estimated oxygen
consumption
Patient trigger
PEEP
Flow curve
HP alarm threshold
Pressure curve
100% O
2
supply
Peak pressure
Patient type
Power supply status
Ventilation type
ACV
ACV
info
HP
HP
0
10
20
30
40
50
60
70
80
90
23
c
m
H2O
P
peak
peak
20,3
c
m
H
2
O
FiO
FiO
2
21
%
M
od
es
Pa
ra
m
<
PE
<
PE
P
16
0
28
0
>
>
v
O
2
100%
2
min
O
2
2
Consumed :
Consumed :
- - l/
m
in
- - l/
m
in
Freeze -> Touch curves
V
Ti
Ti
500
m
l
V
Te
Te
506
m
l
1/4
ACV
ACV
info
HP
HP
0
10
20
30
40
50
60
70
80
90
23
c
m
H2O
P
peak
peak
V
E
F
TOT
TOT
T
I
T
E
I:E
I:E
V
ESP.
ESP.
20,3
P
plat.
plat.
18,1
1:3.0
7,0
15
c
m
H
2
O
c
m
H
2
O
c
m
H
2
O
l/s
m
l/
c
m
H
2
O
bp
m
l/
m
in
0,0
l/
m
in
M
od
es
Pa
ra
m
<
PE
<
PE
Select 4
m
easures
FiO
FiO
2
R
Cstat
Cstat
F/Vt
F/Vt
V
TI
TI
V
TE
TE
PEEP
PEEP
P
mean
mean
1,00
s
3,00
s
500
m
l
506
m
l
5,1
21
29
c
m
H
2
O
7,1
c
m
H
2
O
%
O
2
100%
2
min
1. Press one of the measurements displayed at the bottom of
the screen.
2. Select four measurements to be displayed.
3. Press
to return to the curves screen.
O
2
100%
2
min
0
10
20
30
40
50
60
70
80
90
<PE
┘
HP
00
H
2
O
cm
info
Parameters setting
ACV
ACV
FiO
FiO
2
21
%
V
T
PEEP
PEEP
310
ml
0
cm
cm
H
2
O
Vmax
Vmax
F
30
min
8
bpm
l/
Pa
ra
m
m
M
od
es
s
1/3
1. During ventilation, on the alarms or settings screen, press the
button for two seconds.
Outline curves change to filled curves, and vice-versa.
Summary of Contents for Elisee 350
Page 1: ...Elis e 350 Clinical Manual English Making quality of care easy Respiratory Care solutions...
Page 2: ...Making quality of care easy Respiratory Care solutions...
Page 4: ......
Page 6: ...iv...
Page 10: ...4 102 NOT013281 8...
Page 20: ...14 102 NOT013281 8...
Page 50: ...44 102 NOT013281 8...
Page 86: ...80 102 NOT013281 8...
Page 109: ...Making quality of care easy Respiratory Care solutions...