45
│
5.Settings
In Menu “5. Settings” the system parameters are set.
The menu is closed by pressing “esc” or selecting “Exit
settings”.
By no means does the controller replace any
safety elements in a heating circuit, DHW
circuit, solar circuit and in electric devices of
a heating system!
5.1. Settings heating circuit (Heating circ.)
5.1.1. Operating mode
Heating
= automatic operating mode for a heating circuit following the preset desired
temperatures, periods and heating curves. A heating circuit is switched on if all currently set
temperature and time conditions for heating are met.
Cooling
= operating mode for a heating circuit following the preset desired temperatures,
periods and heating curves. A heating circuit is switched on if all currently set temperature and
time conditions for cooling are met.
Heating/cooling
= automatic heating and cooling operating when the transition between a
heating and cooling modes is done by an external switch set in menu 5.1.19 (Room unit) to
sensor type = season.
Ref. value
= a special operating mode for a heating circuit, keeping a constant flow temperature
set in menu 5.1.4. The controller ignores all other set desired temperatures, periods and
heating curve.
Ref. value
= a special operating mode for a heating circuit, keeping a constant flow temperature
set in menu 5.1.4. The controller ignores all other set desired temperatures, periods and
heating curve.
5.1.2. Summer/Winter day
If this temperature is exceeded at the outdoor sensor in the day period (comfort mode) of the
heating circuit, the controller will turn off the heating circuit and switch to the Summer mode.
When the outdoor temperature drops below this value, the heating circuit will be turned on
again and switched to Winter mode.
5.1.3. Summer/Winter night
If this temperature is exceeded at the outdoor sensor in the night period (setback mode) of the
heating circuit, the controller will turn off the heating circuit and switch to the Summer mode.
When the outdoor temperature drops below this value, the heating circuit will be turned on
again and switched to Winter mode.
5.1.4. Heating circuit refer.
This menu is available only when the operating mode Ref. value is set in menu
5.1.1.
This is the fixed heating water temperature for the operating mode Ref. value set in menu
5.1.1.