3. Periods
Menu 3. Periods contains settings for time, date and
operating times for the heating circuit.
The menu is closed by pressing “esc” or selecting “Exit
periods”.
The associated temperature reference values
are specified in Menu 5. Settings.
3.1. Time & Date
This menu is used to set the current time and date.
For system data statistics it is essential for the time to be set accurately on the
controller. Please note that the clock will stop if the mains voltage is interrupted,
and afterward must be reset. Incorrect time may result in data being cleared,
recorded incorrectly or overwritten.
3.2. Daylight saving time
Setting of an automatic change to and from DST (Daylight Saving Time).
3.3. Heating Circuit (time program)
This menu is used to select the daytime (Comfort) mode times for the heating circuit; three
time periods can be specified for each weekday and copied to the following days.
Unspecified times are automatically considered to be night-time (setback)
mode. The set times are only taken into account in the “Automatic” heating
circuit operating mode.
3.4. Heating Circuit Comfort (time program)
This menu can be used to select a time range for each day of the week in which the heating
circuit is supplied with a comfort temperature increased by the value set in menu 5.1.8. This
period can be used e.g. for quick heating in the morning after a longer operation in the night
(setback) mode.
3.5. Hot water enable (time program)
In this menu, the approval times for the DHW heating to temperatures set in menu 5.3.3
(DHW reference) are selected. For every weekday 3 periods can be determined and copied
in the following days.
3.6. DHW heating - comfort (time program)
This menu used to select a time range for each day of the week in which the DHW is heated
to comfort temperature set in menu 5.3.4 (DHW comfort).
In times that are not set in menu 3.5 and 3.6, DHW is heated to temperatures
set in menu 5.3.2 (Hot water minimum)