29
│
E. SYSTEM SETTINGS
To set up the system correctly, we recommend using the Setup Wizard when starting
the controller for the first time. Then it is advisable to browse through the following
chapters and make further setting adjustments if needed.
E.1. CONTROLLER OPERATION
The display
shows in text
and graphical mode the
hydraulic variant, desired
and measured values and
other text information.
The hydraulic variant dis-
played is just an example!
The „esc“ key (c)
is used
to cancel an entry or to exit
a menu.
The keys
are assigned
context functions; their
actual function is shown in
the display right above the
respective key; the right-
hand key generally has a
confirmation and selection
function. Possible functions
of keys:
+/-
increase / decrease
values
▼/▲ scroll down / up menu
Yes/No
confirm / reject
Info
further information
Back
to previous
OK
confirm selection
The LED light
is used to
indicate the status:
it is lit green
– a relay is
switched on and the Controller
works correctly
it is lit red
–
Auto mode is set
and all relays are off
it flashes slowly red
–
Manual mode is set
it flashes fast red
– an error
is present
The graphics mode appears if no key is pressed for 2 minutes
or after exiting the main menu with “esc“. The temperature
overview appears when you press the left button. Tapping the
button again leads back to the graphic overview. Pressing the
“esc“ key in the graphics mode takes you directly to the main
menu.
Before plugging the pump station into a power socket for the first time, make sure that:
• the entire heating system is completely pressurized and air bled
• all safety elements of the system are installed and put into operation
• all temperature sensors are installed in their installation positions
• all valves and stopcocks are open that shall be opened during operation of the
heating system
After the load unit is plugged into a power socket
, the TRS6 BIOMIX controller automatically
starts in the mode of language, date and time settings selection. You will then be asked about
running the Setup Wizard. Commissioning procedure with the Setup Wizard is described
in the SETUP WIZARD chapter. Either a simple heating curve can be set (see menu 5.1.5.
Heating curve), or a split one (see the chapter SETTING A SPLIT HEATING CURVE). A
simple heating curve is sufficient supposed a room temperature sensor or a Caleon room unit
is installed.