C.2.4. Variant 2
A system with a solid fuel boiler w. manual stoking, one heating circuit, a thermal store and
a hot water storage tank. The BIO MIX Load Unit ensures space and DHW heating and
heat storage in the thermal store. It is recommended to use a Caleon room unit or a room
temperature sensor for a more precise control of the room temperature. To ensure DHW
heating also in periods when the boiler is extinguished, it is recommended to install an electric
heating element fitted with an adjustable thermostat in the hot water storage tank.
Locations of temperature sensors
S1 – lower temperature sensor in a thermal store (shall be ordered separately,
code 9109)
S2 – upper temperature sensor in a thermal store
S3 – temperature sensor in a hot water storage tank
S4 – temperature sensor at the outlet from a solid-fuel boiler
S5 – heating water temperature sensor (in a sheath inside the load unit)
S6 – outdoor temperature sensor
Basic hydraulic diagram
DESCRIPTION
KK
ball valve
1
RegulusBIO Load Unit
ZV
check valve
2
boiler
VK
drain valve
3
combination thermal store
REDV
pressure reducing valve (5 bar)
4
hot water storage tank
SVE
expansion vessel service valve
5
heating system
DOCHV
thermal safety relief valve (e.g. BVTS)
6
heat exchange pump station
TSV TV
anti-scald valve
7
safety kit*
PV-TOP
heating system safety valve
*
the safety kit involves a test valve,
check valve, drain valve, safety valve,
pressure gauge and outlet to connect
an expansion vessel
EN-TV
DHW expansion vessel
EN-TOP
heating system expansion vessel
AOV
automatic air vent valve
MFB
Magnet Filterball
PV-TV
DHW safety valve