C
HAPTER
3
10
Viper/Viper 4+ Installation & Operation Manual
4. Release the power button and note the power button color. If the button is:
•
Green - Hardware is working properly. The cause of the black screen is likely a software issue.
Reload the software on the Viper 4+.
•
Yellow - Hardware is functioning properly but the firmware may be corrupt. Use the thumb drive
with the appropriate firmware to reinstall the firmware.
•
Red - A hardware issue has occurred. Contact a distributor to schedule the Viper 4+ to be returned
to the Raven service department for analysis and repair.
•
No Color - If the power button does not display a color, this could indicate that there is no power
being applied to the Viper 4+. Check the power and input with the voltmeter and troubleshoot any
external power issues. If power is present at the Viper 4+ power plug, contact your distributor to
return the Viper 4+ to the Raven service department for analysis and repair.
UNDERSTANDING ICON BORDER COLORS
The function of each icon is indicated by the border around the icon. If the icon has a gold border it is an icon that
can be selected and opened to make adjustments. Icons with a gray, or no, border are informational and will not
perform an action if pressed.
DEVICE SHUT DOWN
When finished using the ROS device:
1. Close any active jobs by selecting the home icon in the lower, right corner of the display.
2. Touch the administrator or user panel and select the shut down icon.
INITIAL START UP OVERVIEW
LANGUAGE AND UNITS
1. Touch the done icon to clear the initial machine configuration prompt.
2. Touch the administrator panel at the top of the display and select the user profile option.
3. Touch the location information tab and set the desired language at the bottom of the tab display.
4. If desired, update the time zone to the local universal coordinated time (UTC).
5. Touch the unit preferences tab and select the desired base and pressure units for display. These units will be
used to enter the machine configuration and calibrate control systems.
NOTE:
Refer to Chapter 5, Administrator and User Profiles, for additional details on setting up user profiles
on the ROS device.
Administrator
or User Panel
Shut
Down
Home
Done
Administrator
or User Panel
User
Profile
Summary of Contents for viper
Page 16: ...CHAPTER 2 8 Viper Viper 4 Installation Operation Manual ...
Page 48: ...CHAPTER 6 40 Viper Viper 4 Installation Operation Manual ...
Page 67: ...File Manager 59 FILE MANAGER ...
Page 68: ...CHAPTER 7 60 Viper Viper 4 Installation Operation Manual ...
Page 112: ...CHAPTER 9 104 Viper Viper 4 Installation Operation Manual ...
Page 174: ...CHAPTER 16 166 Viper Viper 4 Installation Operation Manual ...
Page 176: ...CHAPTER 17 168 Viper Viper 4 Installation Operation Manual ...