P/N 016-0171-493 Rev. I
193
Calculating the Calibration Values
11.
Toggle the section or master switch off.
12.
Read the value displayed on the field computer Total Volume button. This value should be within ± 3% of
the meter cal value printed on the flow meter tag.
13.
To confirm accuracy, reset the Total Volume to 0 and repeat the above process several times. Always ‘zero
out’ the Total Volume display before toggling the section switch on.
Note:
The above process is usually sufficient to check the flow meter calibration. For best results, set the
Meter Cal value to 100 [378] and repeat the above procedure to dispense exactly 100 gallons [378
L] through the flow meter.
To verify the flow meter calibration:
1.
Fill the applicator tank with a predetermined volume of liquid (i.e. 250 gallons [946 L]).
Important:
Do not rely on graduation markings/numbers molded into the applicator tank.
2.
On the field computer Home screen, touch the Tools Menu icon.
3.
Select the Product Control icon from the System menu.
4.
On the Product Control Configuration screen, touch the Volume/Area Settings button.
5.
Use the on-screen keypad to enter a value of 0 and touch the Accept icon.
6.
Empty the applicator tank under normal operating conditions.
7.
Return to the Total Volume displayed on the field computer and read the new value. The total volume value
should match the known volume (± 3%) used to fill the applicator tank.
8.
If the total volume value displayed differs from the known volume by greater than 3%, use the following
formula
Where MC = the Meter Cal value used during the test, Vm = the Volume measured by the field computer,
Vk = the known Volume in the applicator tank and CMC = the Corrected Meter Cal.
For Example:
A set meter cal of 720 [190] is used to dispense 250 gallons [946 L] through the flow meter. At the end of
the test, the field computer reads a measured volume of 260 gallons [984 L]:
or
Therefore, the corrected meter cal is 749 [198].
9.
Enter the corrected meter cal value before resuming application.
MC
Vm
×
Vk
------------------------
CMC
=
720
260
×
250
------------------------
749
=
190
[
]
984
[
]
×
946
[
]
----------------------------------
198
[
]
=
Summary of Contents for Envizio Pro
Page 3: ......
Page 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 197: ...Chapter 10 182 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 229: ...Appendix D 214 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 285: ...Index 270 Envizio Pro and Envizio Pro II Installation and Operation Manual ...