MKM Multi-Kilowatt Module 

User Manual 

MKM Multi-Kilowatt Module User Manual 

Newark, New York | 315-332-7100 | Fax: 315-331-7800 

©2013 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice. 

The information contained herein is for reference only and does not constitute a warranty of performance. • 

10 APR 15 UBI-05342 Rev: A 

 

 

 

P/N:

 

URB0001

 

P/N:

 

URB0001

SMB

 

P/N:

 

URB0003

 

P/N:

 

URB0003

SMB

 

Summary of Contents for URB0001

Page 1: ...Fax 315 331 7800 2013 Ultralife Corporation www ultralifecorp com All information is subject to change without notice The information contained herein is for reference only and does not constitute a w...

Page 2: ...lity Information and descriptions contained in this manual are the property of Ultralife Corporation Distribution and or reproduction in part or in whole are expressly forbidden without written consen...

Page 3: ...and does not constitute a warranty of performance 10 APR 15 UBI 05342 Rev A Page 3 of 11 CONTENTS 1 ABOUT THIS MANUAL 4 1 1 SYMBOLS USED 4 1 2 CAUTION 5 1 3 WARNINGS 5 1 4 HIGH VOLTAGE 5 1 5 CLASS 9...

Page 4: ...ent important safety advice and appear in the form of WARNINGS and CAUTIONS against possible hazards to people or equipment respectively These safety WARNINGS and CAUTIONS must be followed at all time...

Page 5: ...ll charging recommendations Do recharge batteries every 6 months minimum Follow all safety instructions Do not stack over 4 units high Do use 2 man lift 1 3 Warnings Do not expose to water Do use only...

Page 6: ...fe and safety characteristics Nominal voltage for the listed models is 24VDC with an overall range of 23V to 28 8VDC The MKM products have Ultralife SmartCircuit Protection electronics and fuel gaugin...

Page 7: ...Bus and CAN Bus among others The Communication port is used for State of Charge and other internal battery statuses Verify the version MKM you are using and the communication protocol before proceedin...

Page 8: ...connector Both contacts actuate to the normal position on power up if the MKM is functioning properly The relay is rated at 1A continuous and 12V maximum The external balancing resistor is recommende...

Page 9: ...products have been designed to be utilized with advanced Sealed Lead Acid chargers Power supplies and Lithium Ion chargers Please consult factory to verify the applicability of a proposed charging sol...

Page 10: ...ines for safe installation Refer to the latest edition of the National Electric Code for additional details For series installations it is recommended a cutoff voltage be set to 23 25V per series modu...

Page 11: ...e is programmed at the factory for the specifics of the MKM chemistry There are a few correction factors needed to use the data stored in the fuel gauge Voltage must be multiplied by 8 Current must be...