Appendix I
238
Envizio Pro™ and Envizio Pro II® Installation and Operation Manual
Remote Calibration Console
The optional tank calibration kit (P/N 117-0171-302) allows the operator to perform all the necessary calibration
operations from the air cart making calibration of the OmniSeed system quick and convenient. The remote tank
console allows the operator to prime metering rollers and perform the catch test while watching the air cart
operation which can help the operator make correct system adjustments prior to starting a seeding operation in
a field.
Note:
When performing calibration with the remote tank console, the Envizio Pro field computer must be
powered up. To ensure that the tank console programs the system properly, the field computer
should not be used to navigate the calibration screens or the meter weight settings. The tank
calibration kit requires a hydraulic drive system to connect the remote tank console.
Kit Contents
TABLE 1.
Remote Tank Calibration Kit (P/N 117-0171-302)
Console Connection
Note:
The remote tank console and cable should only be connected when using the console to calibrate
the system. Remove the remote tank console and console cable and replace the dust cap when
storing or operating the air cart.
To connect the remote tank console:
1.
Carefully insert the round 4-pin connector on the calibrator cable to the 4-pin port on the back of the tank
console. Be sure to line up the keyway on both the port and connector before securing the connector.
2.
Carefully insert the round 8-pin connector on the calibrator cable to the 8-pin port on the back of the tank
console. Be sure to line up the keyway on both the port and connector before securing the connector.
3.
Locate the 6-pin Deutsch connector labeled ‘Remote Cal’ on the air cart control cable. The ‘Remote Cal’
connector should be located on the left side of the air cart near the metering rollers.
4.
Remove the dust cap from the ‘Remote Cal’ connector and insert the 6-pin Deutsch connector on the
calibrator cable.
WARNING
The metering rollers will turn during the
calibration procedure. Keep away from moving
components when performing a catch test using
the remote tank console.
Be aware of bystanders and alert anyone
around the air cart when performing the
calibration process.
Part/Description
Part Number
Console, Remote Tank
063-3001-004
Cable, Remote Tank Calibrator 115-3001-039
Summary of Contents for Envizio Pro
Page 3: ......
Page 13: ...Table of Contents x Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 51: ...Chapter 4 36 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 65: ...Chapter 5 50 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 193: ...Chapter 9 178 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 197: ...Chapter 10 182 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 229: ...Appendix D 214 Envizio Pro and Envizio Pro II Installation and Operation Manual ...
Page 285: ...Index 270 Envizio Pro and Envizio Pro II Installation and Operation Manual ...