Remote Commands
R&S
®
ZNH
254
User Manual 1334.5985.02 ─ 02
CALCulate<1...2>:DELTamarker<1...6>:X:RELative
...........................................................256
CALCulate<1...2>:DELTamarker<1...6>:Y?
....................................................................... 256
CALCulate<1...2>:MARKer<1...6>[:STATe]
....................................................................... 257
CALCulate<1...2>:MARKer<1...6>:AOFF
..........................................................................257
CALCulate<1...2>:MARKer<1...6>:FUNCtion:STRack[:STATe]
............................................257
CALCulate<1...2>:MARKer<1...6>:MAXimum[:PEAK]
........................................................ 258
CALCulate<1...2>:MARKer<1...6>:MAXimum:NEXT
..........................................................258
CALCulate<1...2>:MARKer<1...6>:MINimum[:PEAK]
......................................................... 258
CALCulate<1...2>:MARKer<1...6>:MODE
.........................................................................259
CALCulate<1...2>:MARKer<1...6>:X
................................................................................ 259
CALCulate<1...2>:MARKer<1...6>:X:SLIMits<1...2>[:STATe]
.............................................. 260
CALCulate<1...2>:MARKer<1...6>:X:SLIMits<1...2>:LEFT
..................................................260
CALCulate<1...2>:MARKer<1...6>:X:SLIMits<1...2>:RIGHt
.................................................261
CALCulate<1...2>:MARKer<1...6>:Y?
.............................................................................. 261
CALCulate<1...2>:DELTamarker<1...6>[:STATe]
<State>
This command turns delta markers on and off.
If you set the suffix at DELTamarker to 1, or use no suffix, the R&S
ZNH interprets this
as delta marker 2 because the first marker has to be a normal marker. If more than one
normal marker (2 to 6) is already active, the command turns these markers into delta
markers. If no delta marker is active yet, the command activates the delta marker and
positions it on the trace maximum.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:DELT3 ON
Turns on delta marker 3 or turn marker 3 into a delta marker.
CALCulate<1...2>:DELTamarker<1...6>:AOFF
This command turns off all active delta markers.
This command is an event and therefore has no query and no *RST value.
The numeric suffix at CALCulate is irrelevant for this command. The numeric suffix at
DELTamarker selects the deltamarker.
Example:
CALC:DELT:AOFF
Turns off all delta markers.
Usage:
Event
CALCulate<1...2>:DELTamarker<1...6>:MAXimum[:PEAK]
This command positions a delta marker on the current trace maximum.
Remote Control - Commands