Instrument Functions
R&S
®
NRP2
95
User Manual 1173.9157.02 ─ 03
Fig. 4-26: Display mode-specific settings
The available configuration parameters depend on the selected display mode.
●
"Dig"
In the
digital
display, the resolution is adjustable, see
For "TimeSlot AV" measurements, the timeslot to be displayed can be chosen.
●
"D&A"
In the hybrid
digital & analog
mode, the resolution of the digital display (
on page 95) and the scaling for the analog meter are adjustable (
●
"Graph"
In the graphical representation, all further settings are provided in the corresponding
diagrams. Once the window has been expanded, as described in
on page 92, additional submenus provide trigger, marker or scale-setting parameters.
Setting the resolution
The resolution of a digital measurement result display can be set in 4 stages, designated
as 1
dB, 0.1
dB, 0.01
dB and 0.001
dB. If dB, dBm or dB
μ
V is selected as the unit, the
number of places after the decimal point is set directly. In the linear mode (W,
Δ
%, 1),
the number of digits after the decimal point depends on the selected resolution and the
magnitude of the result. A digit is added or removed for each resolution stage that is
added or removed.
The selected resolution also influences the automatic selection of the averaging number
in the "Normal" mode (see
chapter 4.2.3, "Filter / averaging"
the selected resolution, the higher the averaging number to correspond to the number of
digits.
Resolution (dB)
Sets the resolution for the measurement result display.
The resolution of the displayed result corresponds to the selected setting.
SCPI command:
Setting the Analog Meter
The analog scale in the hybrid
digital & analog
display mode ("D&A") is set in the "Meter
Scaling" dialog box. The dialog box opens after pressing the "Analog Meter" softkey.
Displaying measurement results
Summary of Contents for NRP2
Page 1: ...R S NRP2 Power Meter User Manual User Manual 2 1173 9157 02 03 Test Measurement...
Page 20: ......
Page 24: ...Contents R S NRP2 6 User Manual 1173 9157 02 03...
Page 40: ...Putting into Operation R S NRP2 22 User Manual 1173 9157 02 03 Starting the R S NRP2...
Page 352: ...Maintenance R S NRP2 334 User Manual 1173 9157 02 03 Storage...
Page 366: ...Error Messages and Troubleshooting R S NRP2 348 User Manual 1173 9157 02 03 Bootmenu...
Page 382: ...Remote control interfaces R S NRP2 364 User Manual 1173 9157 02 03 USB interface...
Page 394: ...Standard Configurations R S NRP2 376 User Manual 1173 9157 02 03...
Page 422: ...Compatibility Information R S NRP2 404 User Manual 1173 9157 02 03...