5.8
5.2.4 Responses to Queries
A query is defined for each setting command unless explicitly specified otherwise. It is formed by adding
a question mark to the associated setting command. According to SCPI, the responses to queries are
partly subject to stricter rules than in standard IEEE 488.2.
1. The requested parameter is transmitted without header.
Example:
SENSe:FREQuency:MODe
Response:
SWE
2. Maximum values, minimum values and all further quantities which are requested via a special text
parameter are returned as numerical values.
Example:
FREQuency? MAX
Response:
3000000000
3. Numerical values are output without a unit. Physical quantities are referred to the basic units.
Example:
FREQuency?
Response:
100000000
for 100 MHz
4. Truth values <Boolean values> are returned as 0 (for OFF) and 1 (for ON).
Example:
OUTPut:FILTer:STATe?
Response:
1
5. Text (character data) is returned in a short form (see also 5.2.5"Parameters").
Example:
SENSe:FREQuency:MODe?
Response:
SWE
Summary of Contents for EM510
Page 4: ......
Page 6: ......
Page 12: ...EM510 Contents 4065 7763 32 01 00 8...
Page 17: ...Characteristics EM510 2 5 4065 7763 32 01 00 Fig 2 1 Front View Fig 2 2 Rear View...
Page 18: ...EM510 Characteristics 4065 7763 32 01 00 2 6 Fig 2 3 Modules...
Page 22: ...EM510 Characteristics 4065 7763 32 01 00 2 10 Fig 2 4 EM510 Detailed Block Diagram...
Page 24: ...EM510 Characteristics 4065 7763 32 01 00 2 12...
Page 30: ...EM510 Installation and Cabling 4065 7763 32 01 00 3 6...
Page 180: ...EM510 Remote Control via LAN 4065 7763 32 01 00 5 144...
Page 183: ...Maintenance and Troubleshooting EM510 6 3 4065 7763 32 01 00...