SENSe Subsystem
:SWEep
4065.7763.32-01.00
5.98
.
.
:SUPPress
Insert current frequency into suppress list. The range is obtained from the bandwidth according to the
following formulae:
SSTARTn = SENSn: FREQ - SENSn:BAND/2
SSTOPn
= SENSn: FREQ + SENSn:BAND/2
The frequency pair is inserted into an empty space of the trace. Free spaces (gaps) are characterized
by a frequency pair with the values 0.0.
Error message:
If the corresponding suppress trace has no free space, an error
-223 "Too much data"
is
generated.
Parameters:
none
*RST state:
none, as command is an event
Example:
SWEep:SUPPress
.
.
.
:SORT
Sort and condense suppress list. The frequency pairs are sorted to an ascending order of the start
frequency. Overlapping is eliminated by extending the frequency pair. The other frequency pair is then
deleted. Gaps within the suppress list are put to the end of the list.
Parameters:
none
*RST state:
none, as command is an event
Example:
SWEep:SUPPress:SORT
Summary of Contents for EM510
Page 4: ......
Page 6: ......
Page 12: ...EM510 Contents 4065 7763 32 01 00 8...
Page 17: ...Characteristics EM510 2 5 4065 7763 32 01 00 Fig 2 1 Front View Fig 2 2 Rear View...
Page 18: ...EM510 Characteristics 4065 7763 32 01 00 2 6 Fig 2 3 Modules...
Page 22: ...EM510 Characteristics 4065 7763 32 01 00 2 10 Fig 2 4 EM510 Detailed Block Diagram...
Page 24: ...EM510 Characteristics 4065 7763 32 01 00 2 12...
Page 30: ...EM510 Installation and Cabling 4065 7763 32 01 00 3 6...
Page 180: ...EM510 Remote Control via LAN 4065 7763 32 01 00 5 144...
Page 183: ...Maintenance and Troubleshooting EM510 6 3 4065 7763 32 01 00...