EM510
Installation and Cabling
4065.7763.32-01.00
3.4
Installing the connector:
1.
Insert the Speakon
NL4FX connector into the socket X40 on the rear panel.
2.
Turn the connector clockwise until it is locked into place and is secured by the safety-latch.
3.
Screw on the fitting for the hose (Fig. 3-2).
Removing the connector:
1.
Unscrew the fitting for the hose (Fig. 3-2).
2.
Press and chuck back the safety-latch of the Speakon
NL4FX connector (Fig. 3-1).
3.
Turn the connector counter-clockwise and withdraw it.
Safety-latch
Fig. 3-1: Connector: Neutrik
Speakon
NL4FX
Fig. 3-2: Hose Fitting
3.5.2 Antenna Connection
The antenna is connected to socket X1 on the rear panel.
- Frequency range: 9 kHz to 32 MHz
- RF level: -137 to +10 dBm, P
max
= 50 mW (+15 dBm)
- Z = 50