SENSe Subsystem
:FREQuency
EM510
5.71
4065.7763.32-01.00
.
.
[:CW|FIXed]? [MINimum|MAXimum]
Query about the receiver frequency.
Parameters:
none
query about the current receiver frequency
MINimum|MAXimum
query about the lowest|highest receiver frequency
Result:
Frequency value in Hz
Example:
FREQuency? -> 801000
.
.
:MODE CW|FIXed|SWEep|MSCan|PSCan
Changing the operating mode of the receiver.
Parameters:
CW | FIXed
receiver monitors a frequency (CW and FIXed have equal
meanings)
SWEep
receiver is in frequency-scan mode (see
SENSe:SWEep
)
MSCan
receiver is in memory-scan mode (see
SENSe:MSCan
)
PSCan
receiver is in panorama-scan mode (see
SENSe:PSCan
)
Note:
The receiver stays on the CW frequency until it starts scanning!
*RST state
CW
Example:
FREQuency : MODE
SWEep
.
.
:MODE?
Query about the receiver operating mode.
Parameters:
none
Result:
CW, SWE, MSC, PSC
Example:
FREQuency:MODE? -> SWE