5.5.3.8 STATus:EXTension Register
This register contains in the CONDition part information on different receiver states which cannot be
assigned to the other registers. Information about the actions the unit has carried out since the last read
out are stored in the EVENt part. The corresponding registers can be queried with the commands
STATus:EXTension:CONDition?
or
STATus:EXTension[:EVENt]?
.
Table 5-7: Bit allocation of STATus:EXTension register
Bit No.
Meaning
0
RX-Data changed
This bit is set if the receiver data were changed by another remote client (see also "
Data Memory
" on page
5.127).
1
FSCAN-Configuration changed
This bit is set if the FSCAN data were changed by another remote client (see also "
Data Memory
" on page
5.127).
2
Signal changed
This bit is set if the received signal changes in level or offset.
3
COR active
This bit is set if the COR relay becomes active.
4
SIGNal > THReshold
This bit is set if the signal level is above the squelch threshold (precondition: squelch is switched on).
5
INPut:ATTenuation:STATe
This bit is set if the input attenuator is switched on.
7
Reserved
8
RX-Settings changed
This bit is set if a parameter was changed by another remote client in the data set "miscellaneous".
9
MSCAN-Configuration changed
This bit is set if the MSCAN data set is changed by another remote client .
10
Reserved
12
MEMory-Data changed
This bit is set if a memory data was changed by another remote client.
13
MEMory-Parameter changed
This bit is set if the query bit was changed by another remote client.
14
PSCAN-Configuration changed
This bit is set if the PSCAN data set is changed by another remote client (PSCAN is an option).
Summary of Contents for EM510
Page 4: ......
Page 6: ......
Page 12: ...EM510 Contents 4065 7763 32 01 00 8...
Page 17: ...Characteristics EM510 2 5 4065 7763 32 01 00 Fig 2 1 Front View Fig 2 2 Rear View...
Page 18: ...EM510 Characteristics 4065 7763 32 01 00 2 6 Fig 2 3 Modules...
Page 22: ...EM510 Characteristics 4065 7763 32 01 00 2 10 Fig 2 4 EM510 Detailed Block Diagram...
Page 24: ...EM510 Characteristics 4065 7763 32 01 00 2 12...
Page 30: ...EM510 Installation and Cabling 4065 7763 32 01 00 3 6...
Page 180: ...EM510 Remote Control via LAN 4065 7763 32 01 00 5 144...
Page 183: ...Maintenance and Troubleshooting EM510 6 3 4065 7763 32 01 00...