Remote Control
R&S
®
FSPN
358
User Manual 1179.4363.02 ─ 01
Example:
//Configure low pass filter
FILT:LPAS ON
FILT:LPAS:FREQ:MAN 500KHZ
Manual operation:
See
See
[SENSe:]FILTer:LPASs[:STATe]
<State>
This command turns a low pass filter for measurements on small carrier frequencies on
and off.
Effects of using thelow pass filter:
●
Auto search feature is turned off (
[SENSe:]ADJust:CONFigure:FREQuency:
●
Signal count is turned off (
[SENSe:]ADJust:CONFigure:FREQuency:COUNt
●
The stop offset is limited to 30 % of the filter cut-off frequency (
●
DC coupling should be used for measurements on carrier frequencies below
1
).
Parameters:
<State>
ON | OFF | 1 | 0
When you turn on the filter, you can define a cutoff frequency
with
[SENSe:]FILTer:LPASs:FREQuency:MANual
*RST:
OFF
Example:
//Turn on low pass filter
FILT:LPAS ON
Manual operation:
See
See
[SENSe:]FREQuency:CENTer
<Frequency>
This command defines or queries (in case of automatic frequency search) the current
signal frequency.
Parameters:
<Frequency>
<numeric value>
Default unit: Hz
Example:
//Query signal frequency
FREQ:CENT?
Example:
//Define center frequency
FREQ:CENT 1GHZ
Common Measurement Settings