OPERATION
2-13
Stop Measurement
Press the
[MODE]
button and the display shows Stop? Press
[N/-]
to continue measurement and
[Y/+]
to stop the
measurement and datalog event. The pump stops automatically
when measurement is stopped. Peak and average values for the
current measurement can be read in idle mode until a new
measurement is started.
Automatic Increment of Site ID
Every time a measurement is taken, the site ID will be
incremented by one automatically in Survey mode.
Variable Alarm Signal
In Survey Mode, if the measurement exceeds the low alarm
limit, the buzzer and flashing alarm are activated and will
beep/flash once per second. The alarms will increase in
frequency as the gas concentration approaches the high alarm
limit reaching 8 times per second when the high alarm has been
exceeded.
Press
[Y/+]
key to clear if latching alarm.