Troubleshooting & Error Messages
DISKETTE DRIVES OR TYPES MISMATCH ERROR - RUN SETUP
Problem
:
The floppy diskette installed in the system does not match the
configuration information listed in the BIOS setup screen. This may
be due to incorrect entries in the BIOS setup screen or the drive may
not be responding at power-up.
Solution(s)
: Press CTRL+ALT+ESC to run the BIOS setup program. Make sure
the BIOS setup entries relating to floppy drives correctly reflect the
attached floppy drives. If a floppy exists, drive A should be set to
"1.4M". If you have no floppy drive, both drive A should be set to
none.
ERROR INITIALIZING HARD DISK 0
Problem
:
The IDE disk controller for drive C cannot be initialized.
Solution(s)
: The EPC-7 uses an internal IDE interface and drive. If it fails, either
the setting is wrong or the system needs repair.
If you are not using an IDE drive, press CTRL+ALT+ESC to enter
the BIOS setup program. Press F3 to enter the Fixed disk menu.
Change the drive type to match the device being used.
EXM CONFIGURATION ERROR
Problem
:
The EXMs installed (or not installed) do not match the configuration
information in the CMOS Setup.
Solution(s)
: Press CTRL+ALT+ESC to run the BIOS setup program. Press F2 to
enter the EXM menu. Verify the information listed on the screen,
save any changes and reboot.
If necessary, refer to the section
EXM Setup Screen
, shown in Chapter
4 of this manual, and/or refer to your EXM manual(s) for more
details.
9
9
Page 85
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com