Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing Node Hard Drives
Quantum DXi6902 User’s Guide
85
Caution:
Powering down the system incorrectly or removing the
wrong drive during a drive failure can result in potential
data loss. Do
not
power down the system to replace a hard
drive. Make sure you remove the failed drive and not a
good drive.
Obtaining a
Replacement Node
Hard Drive
Before beginning the replacement procedure, make sure that you have
the required replacement kit. The appropriate replacement drive will be
provided by Quantum Customer Support (see
).
Caution:
Always make sure to use Quantum-supplied new drives as
replacement drives. Never insert a drive that was removed
from another system (not even another DXi6902 system).
You will need the following items to perform this procedure:
• Replacement hard drive kit provided by Quantum Customer
Support.
• ESD grounding wrist strap (included in the replacement kit)
Figure 44 DXi6902 Node Hard
Drive
Illustration
Description
Replacement hard drive
for DXi6902 Node
(2.5 inch, 900GB)
PN XRRVX (SED)
PN 8JRN4 (non-SED)