General Technical Description
3 — 30
02_0404_0710GB
Technical data:
Electrically operated centralised lubrication pump:
Capacity:
2 l
Output flow rate:
4 cm
3
/min
Lubrication point pressure:
max. 100 bar
Control voltage:
12 V
Service temperature:
--25
°
C to +70
°
C
Lubricant:
Multipurpose grease NLGI Class 2
or
Mineral oil with min. 40 mm
2
/s
Check the fill level in the centralised lubrication system on a daily
basis and fill up the grease distributor as required.
Maintenance chart:
Checking fill level of centralised lubrication
system
Operating elements are also integrated in the control cabinet, de-
pending on the model of the centralised lubrication system.
2
1
Different models available
Item
Designation
1
”Centralised lubrication system” button
2
”Centralised lubrication system” indicator lamp
Continuation next side
With controller card