background image

w w w. l a r i u s . c o m

REV

.

 01 - 04/2020

Manuale Cod. 150113

GIOTTO 

FOR SANITATION

OPERA

TING INSTRUCTIONS

Giotto 220 V

Code: SE9020

Giotto 110 V

Code: SE9021

Giotto 220 V  with

 

gravity hopper 50 Lt.

Code: SE9022

Giotto 110 V  with

 

gravity hopper 50 Lt.

Code: SE9023

English

Summary of Contents for LARIUS GIOTTO

Page 1: ...04 2020 Manuale Cod 150113 GIOTTO FOR SANITATION OPERATING INSTRUCTIONS Giotto 220 V Code SE9020 Giotto 110 V Code SE9021 Giotto 220 V with gravity hopper 50 Lt Code SE9022 Giotto 110 V with gravity h...

Page 2: ...ear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian Due to a constant product im...

Page 3: ...or sanitation A C D B E H G F I M N J K L O P Q R S T U V WARNINGS p 4 USE p 5 WORKING PRINCIPLE p 6 TECHNICAL DATA p 6 DESCRIPTION OF THE EQUIPMENT p 7 TRANSPORT AND UNPACKING p 9 CONDITIONS OF GUARA...

Page 4: ...uipment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has...

Page 5: ...quid flammable USE SANITIZING PRODUCTS SPRAYING EQUIPMENT The spraying of liquids under high pressure allows you covering large surfaces with sanitizing agents thus reducing the presence of bacteria f...

Page 6: ...pump An electric diaphragm pump is used for high pressure spraying without air known as airless The pump is powered by an electric motor coupled with a cam shaft The shaft acts on the hydraulic pisto...

Page 7: ...eter 4 Setting valve 5 Hydraulic oil filling cap Pos Description 6 Hydraulic body 7 Recirculation Open Close valve 8 Recirculation pipe delivery connection 9 Recirculation tube 10 Product suction tube...

Page 8: ...9 Recirculation tube 11 Product delivery pipe connection 12 Power supply cable Pos Description 13 PVC tank 50 Lt 14 ON OFF switch of the equipment Gravity hopper version 50 Lt The machine is supplied...

Page 9: ...and cleaning of components causing malfunction wear or damage to the equipment or any of its parts improper use of the equipment use that does not conform with applicable na tional legislation incorr...

Page 10: ...the equipment The pump is earthed through the earth cable of the supply The gun is earthed through the high pressure flexible hose All the conductors near the work area must be earthed Always check th...

Page 11: ...h a maximum length of 50 mt Higher lengths and lower dia meters can provoke excessive voltage falls and also an anomalous working of the equipment CONNECTION OF THE TOOLING TO THE POWER SUPPLY Check t...

Page 12: ...come into contact with aluminium parts of the equipment can provoke dangerous chemical reactions with risk of explosion WASHING OF THE NEW EQUIPMENT Theequipmenthasalreadybeenadjustedatourfactorywith...

Page 13: ...nob J3 clockwise so as the machine works at the idle speed Make sure the product recycles from the return tube J4 Close the re circulation valve At this point the machine will continue to suck the pai...

Page 14: ...switch K2 on the ON position and rotate the pressure setting knob K1 slightly clockwise Make sure the solvent recycles the washing fluid from the return tube CLEANING AT THE END WORK Reduce pressure...

Page 15: ...Then substitute the oil every 250 hours CLEANING THE MOTOR COOLING FAN GUARD Clean the motor cooling fan protection guard periodically to ensure the best cooling ROUTINE MAINTENANCE TOP UP HYDRAULIC...

Page 16: ...pressure desired Lack of product Add the product The equipment sucks air Check the suction pipe The drain valve is open Close the drain valve Suction or delivery valve dirty Disassemble the colour bo...

Page 17: ...etriggertoreleasepressure Attheend of the operation insert the gun clamp Openthere circulationvalve O5 toreleaseresidualpressure If the equipment is still under pressure after performing the operation...

Page 18: ...18 GIOTTO FOR SANITATION REV 01 04 2020 Cod 150113 35 37 38 39 10 11 12 13 14 15 17 18 34 40 30 31 32 16 33 1 43 28 19 9 Rif 12488 2 3 4 5 6 7 8 36 26 27 44 46 45 36 20 21 22 25 41 42 23 24 P COMPLETE...

Page 19: ...ck absorber 22 12460 Half joint 23 81019 Dowel 24 81012 Spline Pos Code Description 1 12455 Hydraulic support 5 82017 Cylinder liner 9 31125 Bearing 10 81020 Elastic ring Pos Code Description 25 81014...

Page 20: ...www larius com 20 GIOTTO FOR SANITATION REV 01 04 2020 Cod 150113 23 24 25 26 27 28 29 30 20 19 18 17 16 21 22 13 14 15 12 11 10 31 8 7 6 5 4 3 2 1 9 Q COMPLETE COLOUR BODY...

Page 21: ...lve 10 83004 Screw 11 33005 Washer 12 83001 Colour body fusion 13 83003 Diaphragm insert 14 33007 Washer 15 3199 Feed tube union 16 83002 1 Diaphragm Pos Code Description 17 83002 2 Oil distributor 18...

Page 22: ...d 150113 1 2 6 5 4 3 R Pos Code Description 1 81001 Electric motor 220V 50HZ 1 81003 Electric motor 110V 60Hz 2 86003 Electic box 3 86001 Condenser 220V Pos Code Description 3 86004 Condenser 110V 4 8...

Page 23: ...2020 Cod 150113 S 6 5 3 4 8 7 1 2 Pos Code Description 1 12454 Foot 2 12710 Trolley base 3 37218 Pneumatic wheel 4 91047 Elastic washer Pos Code Description 5 84007 Split pin 6 12711 Trolley handle 7...

Page 24: ...www larius com 24 GIOTTO FOR SANITATION REV 01 04 2020 Cod 150113 T 425 548 17 16 19 18 16 GRAVITY HOPPER 50L GIOTTO RIF 18240...

Page 25: ...Filter 3 18231 Gun extension filter 4 18249 Gravity hopper 50 L 5 20833 Elbow 6 20817 Junction 7 20825 Cock 8 96098 Junction 9 96099 Gas ring 10 18224 Recirculation tube Pos Code Description 11 18223...

Page 26: ...for 30 lt drums Code 3350 1 Suction tube for 200 lt drums Code SE9041 Suction tube for 1000 lt drums Code 18024 Length 15 m Code 18024 20 Length 20 m Code 18024 25 Length 25 m Code 18024 30 Length 30...

Page 27: ...NOTE the filter choice depends on the type of machine and of the product to be sprayed Code 155 Length 60 cm Code 156 Length 100 cm Code SE9060 Length 130 cm Nozzle SFC 13 60 Code SE9061 Length 180 cm...

Page 28: ...zle angle inch mm Filter recom SFC07 20 0 007 0 18 Red 200 M SFC07 40 SFC09 20 0 009 0 23 SFC09 40 Yellow 100 M SFC11 20 0 011 0 28 SFC11 40 SFC13 20 0 013 0 33 SFC13 40 SFC13 60 SFC15 20 0 015 0 38 S...

Page 29: ...NITATION REV 01 04 2020 Cod 150113 V GHIBLI Cod SE9000 ZEUS Cod SE9010 110V Cod SE9011 220V Cod SE9012 Petrol DAL Cod SE9030 with hose reel 50 Lt Cod SE9031 with hose reel 30 Lt Cod SE9032 50 Lt Cod S...

Page 30: ...I n t e n t i o n a l l y b l a n k p a g e...

Page 31: ...ctive 2014 35 Low Voltage LVD nonch alle seguenti norme armonizzate furthermore to the harmonized standards UNI EN ISO 12100 1 2 Sicurezza del macchinario concetti fondamentali principi generali di pr...

Page 32: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...