Faults, Cause and Remedy
7 — 16
06_0081_1111GB
The following section provides a description of possible causes of
remote control operation and their remedies.
Notes
Check the functions of the machine at the control cabinet first or with
the cable remote control.
If the functions cannot be controlled via the cabinet, the radio remote
control is not the cause of the fault
Heavy current
Work on the electrical system and equipment of the machine must
be carried out by a qualified electrician or by instructed persons un-
der the supervision and guidance of a qualified electrician and in
accordance with the electrical engineering rules and regulations.
Notes
Consult the relevant service department at Putzmeister Mörtelma-
schinen GmbH if you cannot rectify the fault by yourself.
Use only original spare parts.
Putzmeister Mörtelmaschinen GmbH accepts no liability for damage
caused as a result of using non-original spare parts.
For more details, see chapter: “General Technical Description” - sec-
tion: “Technical data” and “Rating plate”.
No response after switching on the transmitter.
Cause
Remedy
No operating voltage present.
Check the battery contacts for damage or contamination.
Insert the charged battery into the battery compartment.
Charge the battery completely.
7.5
Radio remote control
(optional)