background image

 

OPERATION MANUAL

 

EDHQ011AA6V3
EDHQ014AA6V3
EDHQ016AA6V3

EDHQ011AA6W1
EDHQ014AA6W1
EDHQ016AA6W1

EDLQ011AA6V3
EDLQ014AA6V3
EDLQ016AA6V3

EDLQ011AA6W1
EDLQ014AA6W1
EDLQ016AA6W1

EBHQ011AA6V3
EBHQ014AA6V3
EBHQ016AA6V3

EBHQ011AA6W1
EBHQ014AA6W1
EBHQ016AA6W1

EBLQ011AA6V3
EBLQ014AA6V3
EBLQ016AA6V3

EBLQ011AA6W1
EBLQ014AA6W1
EBLQ016AA6W1

 

Unit for air to water heat pump system and

options

Summary of Contents for Alterma EDHQ011AA6V3

Page 1: ...A6W1 EDLQ011AA6V3 EDLQ014AA6V3 EDLQ016AA6V3 EDLQ011AA6W1 EDLQ014AA6W1 EDLQ016AA6W1 EBHQ011AA6V3 EBHQ014AA6V3 EBHQ016AA6V3 EBHQ011AA6W1 EBHQ014AA6W1 EBHQ016AA6W1 EBLQ011AA6V3 EBLQ014AA6V3 EBLQ016AA6V3...

Page 2: ...its and heating only units The AD outdoor monoblock unit range consists of two main versions a heating cooling EB version and a heating only ED version Both versions are delivered with an integrated b...

Page 3: ...h low electricity cost tariffs in mind To do this program both the domestic water heating and booster heating schedule timer Refer to Programming in chapter Programming and consulting the schedule tim...

Page 4: ...n is required on the installation Consult your dealer 11 SET TEMPERATURE DISPLAY 9 The display shows the current set temperature of the installation 12 SETTING Not used For installation purposes only...

Page 5: ...ller is set in permission level 2 or 3 refer to Field settings on page 10 the quiet mode button will not be operable Setting up the controller After initial installation the user can set the clock and...

Page 6: ...uring commissioning of the installation When set lower than 25 C only the backup heater will operate In order to avoid overheating space heating is not operable when the outdoor ambient temperature ri...

Page 7: ...her dependent or manually set Five actions per weekday can be programmed totalling 35 actions 2 Quiet mode refer to Programming quiet mode booster heating or domestic water heating on page 9 Switch th...

Page 8: ...t a requirement but will simplify the interpretation of the program later If 2 or more actions are programmed for the same day and at the same time only the action with the highest action number will...

Page 9: ...to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the p...

Page 10: ...nt to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi an...

Page 11: ...or heating mode 1 Use the button to select the operation mode cooling or heating you want to delete 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The...

Page 12: ...er outdoor temperatures i e Lo_A warmer water is required 1 03 Set point at high ambient temperature Hi_Ti the target outgoing water temperature when the outdoor temperature equals or rises above the...

Page 13: ...ure equals or drops below the specified equilibrium temperature When the function is disabled operation of the backup heater is possible at all outdoor temperatures Enabling this function reduces the...

Page 14: ...ra degrees are specified by the domestic hot water step length field setting Correct setting prevents the booster heater from repeatedly turning on and off i e chattering to maintain the domestic hot...

Page 15: ...water temperature for cooling operation 9 04 Overshoot setting defines how much the water temperature may rise above the setpoint before the compressor stops This function is only applicable in heatin...

Page 16: ...hat contact will open and the unit will go in forced off mode 1 When parameter D 01 2 at the moment that the benefit kWh rate signal is sent by the electricity company that contact will close and the...

Page 17: ...eating off temperature 25 14 25 1 C 03 Booster heater operation 1 0 1 04 Freeze up protection function 0 active Read only 5 Equilibrium temperature and space heating priority temperature 00 Equilibriu...

Page 18: ...ff heaters 0 0 1 2 3 01 Unit connection to benefit kWh rate power supply 0 OFF 0 1 2 02 Not applicable Do not change the default value 0 E Unit information readout 00 Software version Read only 01 EEP...

Page 19: ...late or too early Check if the clock and the day of the week are set correctly correct if necessary DISPOSAL REQUIREMENTS Dismantling of the unit treatment of the refrigerant of oil and of other part...

Page 20: ...NOTES NOTES...

Page 21: ......

Page 22: ...4PW51122 1 Copyright Daikin...