PDM is stopped internally The destination drive was removed or used for a
rebuild.
Physical Disk
Physical disk is marked
online
Disk drive restored to normal operation.
Physical disk is marked
online
Disk drive removed from service due to errors. If
necessary, try to force the disk online. See page 96
(WebPAM PROe) or page 139 (CLU).
Physical disk is marked
as dead.
Disk drive failure. Replace the disk drive.
Physical disk is marked
as dead after it was
removed and reinserted
by the user.
Try forcing the disk online. See page 96 (WebPAM
PROe) or page 139 (CLU)
Physical disk has been
reset
Disk drive reset after error and should function
normally.
Physical disk assigned as
global spare
Result of settings or user action. Normal.
Physical disk is no longer
assigned as global spare
Result of settings or user action. Normal.
Physical disk assigned as
dedicated spare
Result of settings or user action. Normal.
Physical disk is no longer
assigned as dedicated
spare
Result of settings or user action. Normal.
Physical disk has been
inserted
A disk drive has been inserted into the VessRAID
subsystem.
Physical disk has been
removed
A disk drive has been removed from the VessRAID
subsystem.
Bad sector is found on
physical disk
Disk drive has a bad sector. The drive should remap
around the bad sector. If this message appears
repeatedly, replace the disk drive.
Error is detected in remap
sectors
Disk drive has a bad remap sectors. If this message
appears repeatedly, replace the disk drive.
Command times out on
physical drive
Disk drive not responding to commands. If this
message appears repeatedly, replace the disk drive.
Reported Event
Corrective Action
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...