Chapter 5: Management with the CLU
157
Managing the Network Connection
The network connection deals with the VessRAID’s Management Port.
•
Making Management Port Settings (below)
Making Management Port Settings
When you log into the VessRAID over your network, you use the VessRAID’s
management port.
Before you change settings, please see “Choosing DHCP or a Static IP Address”
on page 24.
Making Automatic Settings
1.
From the Main Menu, highlight
Network Management
and press Enter.
2.
Highlight the management port and press Enter.
3.
Highlight
NetMgmt Ethernet Port Settings
and press Enter
4.
Highlight
DHCP
and press the spacebar to toggle to
Enabled
.
5.
Press Ctrl-A to save your settings.
Making Manual Settings
1.
From the Main Menu, highlight
Network Management
and press Enter.
2.
Highlight the management port and press Enter.
3.
Highlight
NetMgmt Ethernet Port Settings
and press Enter
4.
Highlight
DHCP
and press the spacebar to toggle to
Disabled
.
5.
Highlight each of the following and press the backspace key to erase the
current value, then type the new value.
•
IP Address
•
Subnet Mask
•
Default Gateway IP Address
•
DNS Server IP Address
6.
Press Ctrl-A to save your settings.
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...