Managing Spare Drives
201
* Press the
button to view physical drive information from this point.
Spare Drive Status
•
OK
– The normal state of a spare drive.
•
Offline
– Not available for use as a spare. Requires corrective action. See
“Physical Drive Problems” on page 280.
Other status conditions involve functions not supported by the LCD panel.
Creating a Spare Drive
Only unconfigured physical drives can be used to make spares. The spare drive
must be the same type of drive, HDD or SSD, as the other drives in disk array.
To create a spare drive:
1.
Press the
or
button until the display says
Array Configure
.
2.
Press the
button and the display says
Auto Configure
.
3.
Press the
or
button until the display says
Advanced Configure
.
4.
Press the
or
button until the display says
Spare Drive Create.
5.
Press the
button again to display a list of unconfigured physical drives
.
6.
Press the
or
button to move through the list
.
Press the
button to
choose a physical drive for your spare drive.
To create a dedicated or revertible spare drive, see “Creating a Spare Drive”
on page 118 (WebPAM PROe) or page 151 (CLU).
Deleting a Spare Drive
To delete a spare drive:
1.
Press the
or
button until the display says
Array Configure
.
2.
Press the
button and the display says
Auto Configure
.
3.
Press the
or
button until the display says
Advanced Configure
.
4.
Press the
or
button until the display says
Spare Drive Delete.
5.
Press the
button again to display a list of spare drives
.
6.
Press the
or
button to choose the spare drive to delete.
7.
Press the
button and the display says
Are you sure? NO.
Caution
If the spare drive you delete is the only spare, the controller will not
rebuild a critical array until you provide a new spare drive.
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...