VessRAID 1740s, 1840s Product Manual
266
Drive Interface Controller
Drive-interface controller
found
Normal.
Drive-interface controller
is NOT found
Restart the VessRAID. See page 81 (WebPAM
PROe) or page 179 (CLU). If this message appears
repeatedly, contact Technical Support. See page 291.
Drive-interface
diagnostics has passed
Normal.
Drive-interface
diagnostics has failed
Restart the VessRAID. See page 81 (WebPAM
PROe) or page 179 (CLU). If this message appears
repeatedly, contact Technical Support. See page 291
Drive-interface controller
has generated a general/
data parity error.
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support. See
page 291.
Enclosure
Enclosure temperature is
above the threshold/
warning threshold
The VessRAID is overheating. Check for airflow
around and through the VessRAID, and verify that all
fans are working. Replace fans as needed.
Enclosure temperature is
above the critical
threshold
The VessRAID is seriously overheating. Check for
airflow around and through the VessRAID, and verify
that all fans are working. Replace fans as needed.
Enclosure temperature is
within the normal range
Normal.
Event Log
Event logging is enabled
Event logging has been successfully enabled.
Event logging is disabled
Event logging has been disabled.
Event log buffer is cleared
in RAM
The event log was cleared.
Event log buffer is cleared
in NVRAM
The non-volatile RAM event log was cleared.
Event log buffer is cleared
in MDD
The MDD (disk drive) event log was cleared.
Host Interface Controller
Host-interface controller
has detected bus reset
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support. See
page 291.
Reported Event
Corrective Action
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...