background image

E Series™ Broadband
Services Routers

ERX™ Module Guide

Release

11.3.x

Published: 2010-09-27

Copyright © 2010, Juniper Networks, Inc.

Summary of Contents for E SERIES BROADBAND SERVICES ROUTERS 11.3.X - ERX MODULE GUIDE REV 27-9-2010

Page 1: ...E Series Broadband Services Routers ERX Module Guide Release 11 3 x Published 2010 09 27 Copyright 2010 Juniper Networks Inc ...

Page 2: ... in JunosE System Basics Configuration Guide Chapter 6 Managing Modules Table 1 on page 3 lists the module combinations supported by ERX routers This book also contains three appendixes Module Protocol Support on page 87 Module LEDs on page 109 Module Name Cross Reference Information on page 115 Product Reclamation and Recycling Program on page 119 For more information about ERX routers and module...

Page 3: ...ry 13 5 0 0 GE I O SFP GE FE GE 1000Base LH 256 MB memory 15 5 0 0 GE I O SFP GE FE GE 1000Base ZX 256 MB memory 17 2 0 0 GE I O MULTI MODE GE FE GE multimode 19 2 0 0 GE I O SINGLE MODE GE FE GE single mode Gigabit Ethernet 2 port 21 5 3 0 GE 2 SFP I O or 2XGE APS I O SFP or GE 2 APS I O SFP GE 2 GE2 1000Base SX 23 5 3 0 GE 2 SFP I O or 2XGE APS I O SFP or GE 2 APS I O SFP GE 2 GE2 1000Base LH 25...

Page 4: ...I MODE OCx STMx ATM or OCx STMx DS3 ATM OC3 STM1ATMmultimodewithAPS MSP redundancy 35 5 0 0 5 3 0 OC3 4 I O SINGLE MODE OCx STMx ATM or OCx STMx DS3 ATM OC3 STM1 ATM single mode intermediate reach without APS MSP redundancy 256 MB memory 37 5 1 2 5 2 0 APS MSP 4XOC3 APS I O SINGLE MODE OCx STMx ATM or OCx STMx DS3 ATM OC3 STM1 ATM single mode intermediate reach with APS MSP redundancy 39 5 0 0 5 3...

Page 5: ...ach with APS MSP redundancy 53 2 0 0 OC3 4 I O LONG HAUL OCx STMx POS OC3 STM1 POS single mode long reach OC12 STM4 ATM 55 5 0 0 5 3 0 OC12 STM4 I O MULTI MODE OCx STMx ATM or OCx STMx DS3 ATM OC12 STM4 ATM multimode without APS MSPredundancy 256 MBmemory 57 2 0 0 128 MB 5 0 0 256 MB OC12 STM4 APS MULTI MODE OCx STMx ATM or OCx STMx DS3 ATM OC12 STM4 ATM multimode with APS MSP redundancy 59 5 0 0 ...

Page 6: ...thout APS MSP redundancy 69 2 0 0 OC12 STM4 APS MULTI MODE OCx STMx POS OC12 STM4 POS multimode with APS MSP redundancy 71 2 0 0 OC12 STM4 I O SINGLE MODE OCx STMx POS OC12 STM4 POS single mode intermediate reach without APS MSP redundancy 73 2 0 0 OC12 STM4 APS SINGLE MODE OCx STMx POS OC12 STM4 POS single mode intermediate reach with APS MSP redundancy 75 2 0 0 OC12 STM4 I O LONG HAUL OCx STMx P...

Page 7: ...ODULE SM SRPs 81 4 1 3 5 0 4 5 1 2 5 2 0 SRP I O SRP 5G SRP 5G 1 GB memory 82 4 1 3 5 0 4 5 1 2 5 2 0 SRP I O SRP 10G SRP 10G 2 GB memory 83 4 0 0 SRP I O SRP 40G PLUS SRP 40G PLUS 2 GB memory 84 5 3 0 SRP SE I O SRP SE10G SRP SE10G 1 GB memory T3 85 4 1 0 128 104 MB 5 0 0 256 MB 4xDS3 ATM I O OCx STMx ATM or OCx STMx DS3 ATM T3 ATM 4 ports 7 Copyright 2010 Juniper Networks Inc ...

Page 8: ...on supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility Not applicable Module redundancy support RJ 45 connectors For 10 Mbps operation use CAT 3 4 or 5 UTP cable For 100 Mbps operation use only CAT 5 UTP cable The transmitted signal complies with IEEE 802 3 802 3u for cable lengths up to 10...

Page 9: ...r information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility Not applicable Module redundancy support LC full duplex Tx power min 15 dBm max 8 dBm Center wavelength 1300 nm Rx input power min 28 dBm m...

Page 10: ... micron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors multimode fiber See Module LEDs on page 109 LEDs See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 10 ERX 11 3 x Module Guide ...

Page 11: ...SFP at the opposite end of the Ethernet connection For example an SFP rated at TX 1310 RX 1550 must be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information Description EFA ASIC Type Ethernet IEEE 802 3z 1000Base SX Capability See Ethernet Modules on page 87 for information about the laye...

Page 12: ...avelength nm Fiber Type 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1490 Pairs with TX 1490 RX 1310 9 microns 10 6 2 miles matching SFP must hav...

Page 13: ... SFP at the opposite end of the Ethernet connection For example an SFP rated at TX 1310 RX 1550 must be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information Description EFA ASIC Type Ethernet IEEE 802 3z 1000Base LH Capability See Ethernet Modules on page 87 for information about the lay...

Page 14: ...0 6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1490 Pairs with TX 1490 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating rang...

Page 15: ...SFP at the opposite end of the Ethernet connection For example an SFP rated at TX 1310 RX 1550 must be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information Description EFA ASIC Type Ethernet IEEE 802 3z 1000Base ZX Capability See Ethernet Modules on page 87 for information about the laye...

Page 16: ...6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1490 Pairs with TX 1490 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range ...

Page 17: ...protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility Not applicable Module redundancy support SC full duplex Tx power min 9 5 dBm max 4 dBm Center wavelength 850 nm Rx input power min 17 dBm max 3 dBm Rated for 275 m 300 yards over 62 5...

Page 18: ... Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 18 ERX 11 3 x Module Guide ...

Page 19: ... and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility Not applicable Module redundancy support SC full duplex Tx power min 11 dBm max 3 dBm Center wavelength 1300 nm Rx input power min 20 dBm max 3 dBm Rated for 550 m 601 yards over 62 5 micron c...

Page 20: ... Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 20 ERX 11 3 x Module Guide ...

Page 21: ...paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information For information about bandwidth and line rate considerations for the GE2 1000Base SX module combination see GE 2 SFP I O Module in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Description FFA ASIC...

Page 22: ...avelength nm Fiber Type 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1490 Pairs with TX 1490 RX 1310 9 microns 10 6 2 miles matching SFP must hav...

Page 23: ...e paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information For information about bandwidth and line rate considerations for the GE2 1000Base LH module combination see GE 2 SFP I O Module in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Description FFA AS...

Page 24: ...terfaces Alarms errors and events Table 6 Single strand SFPs Pairing Maximum Operating Range kilometers Nominal Wavelength nm Fiber Type 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have...

Page 25: ... SFP rated at TX 1310 RX 1550 must be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information For information about bandwidth and line rate considerations for the GE2 1000Base ZX module combination see GE 2 SFP I O Module in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Et...

Page 26: ...2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1490 Pairs with TX 1490 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX...

Page 27: ...ust be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information For information about bandwidth and line rate considerations for the GE HDE module combination see GE 2 SFP I O Module in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Description FFA ASIC T...

Page 28: ...nterfaces Alarms errors and events Table 8 Single strand SFPs Pairing Maximum Operating Range kilometers Nominal Wavelength nm Fiber Type 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must hav...

Page 29: ...X 1550 must be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following corresponding table Single strand SFPs Pairing for more information For information about bandwidth and line rate considerations for the GE HDE module combination see GE 8 I O Module in JunosE Physical Layer Configuration Guide Chapter 5 Configuring Ethernet Interfaces Description FFA AS...

Page 30: ...faces Alarms errors and events Table 9 Single strand SFPs Pairing Maximum Operating Range kilometers Nominal Wavelength nm Fiber Type 10 6 2 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1550 9 microns 10 6 2 miles matching SFP must have th...

Page 31: ... STM1 for ATM Description EFA ASIC Type OC3 STM1 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module ...

Page 32: ...or 50 micron core cable with an optical loss of 7 dB See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 32 ERX 11 3 x Module...

Page 33: ...8 MB OCx STMx ATM line module or the 256 MB OCx STMx DS3 ATM line module Unchannelized concatenated OC3 STM1 for ATM Description EFA ASIC Type OC3 STM 1 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility...

Page 34: ... micron core cable with an optical loss of 7 dB See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 34 ERX 11 3 x Module Guid...

Page 35: ...t the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 15 dBm max 8 dBm Cente...

Page 36: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 36 ERX 11 3 x Module Guide ...

Page 37: ...B OCx STMx ATM line module or the 256 MB OCx STMx DS3 ATM line module Unchannelized concatenated OC3 STM1 for ATM Description EFA ASIC Type OC3 STM 1 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SR...

Page 38: ...le See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 38 ERX 11 3 x Module Guide ...

Page 39: ...the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 5 0 dBm max 0 dBm Center...

Page 40: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 40 ERX 11 3 x Module Guide ...

Page 41: ...ee LC style fiber optic or copper SFPs Single strand SFPs can be used These SFPs work in pairs and require a matching SFP at the opposite end of the Ethernet connection For example an SFP rated at TX 1310 RX 1550 must be paired with an SFP rated TX 1550 RX 1310 with the same maximum operating range See the following table Single strand SFPs Pairing for more information Description EFA ASIC Type OC...

Page 42: ...f 9 micron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors ATM SX LC style fiber optic connectors Tx power min 5 0 dBm max 0 dBm Center wavelength 1310 nm Rx input power min 34 dBm max 7 dBm Rated for 40 km 24 8 miles of 9 micron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors ATM ...

Page 43: ...bles and connectors GE SX LC full duplex Tx power min 3 dBm max 2 dBm Center wavelength 1550 nm Rx input power min 23 dBm max 3 dBm Rated for 70 km 43 4 miles over 10 micron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors GE ZX See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide...

Page 44: ...perating range TX 1310 RX 1490 Pairs with TX 1490 RX 1310 9 microns 10 6 2 miles matching SFP must have the same operating range TX 1490 RX 1310 Pairs with TX 1310 RX 1490 9 microns 40 24 85 miles matching SFP must have the same operating range TX 1310 RX 1550 Pairs with TX 1550 RX 1310 9 microns 40 24 85 miles matching SFP must have the same operating range TX 1550 RX 1310 Pairs with TX 1310 RX 1...

Page 45: ...xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 19 dBm max 14 dBm Center wavelength 1310 nm Rx input power min 30 dBm max 14 dBm Rated for 2 km 1 2 miles over 62 5 micron core cable w...

Page 46: ...ing SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 46 ERX 11 3 x Module Guide ...

Page 47: ...ion supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support LC full duplex Tx power min 19 dBm max 14 dBm Center wavelength 1310 nm Rx input power min 30 dBm max 14 dBm Rated for 2 km 1 2 ...

Page 48: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 48 ERX 11 3 x Module Guide ...

Page 49: ...s that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 15 dBm max 8 dBm Center wavelength 1310 nm Rx input power min 31 dBm max ...

Page 50: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 50 ERX 11 3 x Module Guide ...

Page 51: ...nd applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support LC full duplex Tx power min 15 dBm max 8 dBm Center wavelength 1310 nm Rx input power m...

Page 52: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 52 ERX 11 3 x Module Guide ...

Page 53: ...ule combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 5 0 dBm max 0 dBm Center wavelength 1310 nm Rx input power min 34 dBm max 7 dBm Fiber ty...

Page 54: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 54 ERX 11 3 x Module Guide ...

Page 55: ...12 STM4 for ATM Description EFA ASIC Type OC12 STM4 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line modu...

Page 56: ... micron core cable with an optical loss of 7 dB See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 56 ERX 11 3 x Module Guid...

Page 57: ... 128 MB OCx STMx ATM line module or the 256 MB OCx STMx DS3 ATM line module Unchannelized concatenated OC12 STM4 for ATM Description EFA ASIC Type OC12 STM4 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibi...

Page 58: ... micron core cable with an optical loss of 7 dB See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 58 ERX 11 3 x Module Guid...

Page 59: ...bout the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 15 dBm max 8 dBm Ce...

Page 60: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 60 ERX 11 3 x Module Guide ...

Page 61: ... MB OCx STMx ATM line module or the 256 MB OCx STMx DS3 ATM line module Unchannelized concatenated OC12 STM4 for ATM Description EFA ASIC Type OC12 STM4 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility...

Page 62: ...le See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 62 ERX 11 3 x Module Guide ...

Page 63: ...12 STM4 for ATM Description EFA ASIC Type OC12 STM4 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line modu...

Page 64: ...cron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 64 ERX 11 3 x Module Guide ...

Page 65: ...128 MB OCx STMx ATM line module or the 256 MB OCx STMx DS3 ATM line module Unchannelized concatenated OC12 STM4 for ATM Description EFA ASIC Type OC12 STM4 ATM AAL5 Capability See OCx STMx ATM Modules on page 97 for information about the layer 2 and layer 3 protocols and applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibil...

Page 66: ...cron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 66 ERX 11 3 x Module Guide ...

Page 67: ...RX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 19 dBm max 14 dBm Center wavelength 1310 nm Rx input power min 30 dBm max 14 dBm Rated for 2 km 1 2 miles over 62 5 micron core cabl...

Page 68: ...ing SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 68 ERX 11 3 x Module Guide ...

Page 69: ...eatures ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 19 dBm max 14 dBm Center wavelength 1310 nm Rx input power min 30 dBm max 14 dBm Rated for 2 km 1 2 miles over 62 5 micron ...

Page 70: ...ing SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 70 ERX 11 3 x Module Guide ...

Page 71: ...ions that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 15 dBm max 8 dBm Center wavelength 1310 nm Rx input power min 31 dBm m...

Page 72: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 72 ERX 11 3 x Module Guide ...

Page 73: ...lications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 15 dBm max 8 dBm Center wavelength 1310 nm Rx input power min 31 ...

Page 74: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 74 ERX 11 3 x Module Guide ...

Page 75: ...ns that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 5 0 dBm max 0 dBm Center wavelength 1310 nm Rx input power min 34 dBm ma...

Page 76: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 76 ERX 11 3 x Module Guide ...

Page 77: ...pplications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy NOTE Line module redundancy is not supported on the ERX310 router Module redundancy support SC full duplex Tx power min 5 0 dBm max 0 dBm Center wavelength 1310 nm Rx input power min ...

Page 78: ... LEDs See Monitoring SONET SDH Interfaces in JunosE Physical Layer Configuration Guide Chapter 3 Configuring Unchannelized OCx STMx Interfaces Alarms errors and events Copyright 2010 Juniper Networks Inc 78 ERX 11 3 x Module Guide ...

Page 79: ...res ERX1440 router Model compatibility SRP 40G SRP 40G PLUS SRP module compatibility Not applicable Module redundancy support LC full duplex connector Transmit power min 10 dBm max 3 dBm Center wavelength 1310 nm Receive input power min 18 dBm max 3 dBm Rated for 2 km 1 2 miles of 9 micron core cable See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors Se...

Page 80: ... applications that this module combination supports Software features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility Multiple SMs provide redundancy See JunosE Physical Layer Configuration Guide Chapter 6 Managing Tunnel Service and IPSec Service Interfaces Module redundancy support Not applicable Cables and con...

Page 81: ...hed end of life Description Not applicable Type Ethernet IEEE 802 3 10 100Base T RS 232 Capability Not applicable Software features ERX705 Broadband Services Router Model compatibility SRP 5G SRP module compatibility 1 1 redundancy Module redundancy support Terminal blocks BNC 75 ohm Wire wrap posts RJ 45 RS 232 DB 9 See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables ...

Page 82: ...n has reached end of life Description Not applicable Type Ethernet IEEE 802 3 10 100Base T RS 232 Capability Not applicable Software features ERX710 Router ERX1410 Router Model compatibility SRP 10G SRP module compatibility 1 1 redundancy Module redundancy support Terminal blocks BNC 75 ohm Wire wrap posts RJ 45 RS 232 DB 9 See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information ...

Page 83: ...2 3 10 100Base T RS 232 Capability Not applicable Software features ERX1440 router Model compatibility SRP 40G SRP 40G PLUS SRP module compatibility 1 1 redundancy Module redundancy support Terminal blocks BNC BNC 75 ohm Wire wrap posts RJ 45 RS 232 DB 9 See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring M...

Page 84: ...10 100Base T RS 232 Capability Not applicable Software features ERX310 router Model compatibility SRP SE10G SRP module compatibility Not applicable Module redundancy support RJ 45 RS 232 DB 9 See ERX Hardware Guide Chapter 5 Cabling ERX Routers for more information Cables and connectors See Module LEDs on page 109 LEDs See Monitoring Modules in JunosE System Basics Configuration Guide Chapter 6 Ma...

Page 85: ...tware features ERX7xx models ERX14xx models ERX310 router Model compatibility SRP 5G SRP 10G SRP 40G SRP 40G PLUS SRP SE10G SRP module compatibility 1 N redundancy Module redundancy support 75 ohm connector The line interface unit supports two line buildouts 0 68 5 m 0 225 feet 69 137 m 226 450 feet Signal strength is software controlled The transmitted signal complies with ANSI T1 102 1993 Digita...

Page 86: ......

Page 87: ...by Juniper Networks If you use a feature before it has been fully qualified it is your responsibility to ensure that it operates correctly in your targeted configuration This appendix contains the following sections Ethernet Modules on page 87 OCx STMx GE FE Modules on page 94 OCx STMx ATM Modules on page 97 OCx STMx POS and OC48 Modules on page 99 Service Modules on page 102 Unchannelized T3 Modu...

Page 88: ...RP and GRE support server side Yes Dynamic interfaces Yes Ethernet raw mode encapsulation in Martini layer 2 circuits No F4 OAM and F5 OAM ATM administration No FDL facilities data link Yes Firewall No Frame Relay Yes including fast reconnection of PPPoE subscribers ICR Yes IEEE 802 3ad link aggregation No IEEE 802 3ah OAM link fault management Yes IP Yes IP multicast No IP reassembly for tunneled...

Page 89: ...ide Yes LNS support peer side No Local loopback No MDL maintenance data link Yes Mobile IP home agent Yes MPLS Yes MPLS L2VPNs over the LAGs configured between customer edge CE and provider edge PE devices No Multilink Frame Relay No Multilink PPP Yes Network Address Translation NAT No NBMA multipoint ATM Yes OSPF Yes Packet Mirroring No Packet over SONET No PPP Yes PPPoE No Remote loopback 89 Cop...

Page 90: ...interfaces Yes VPLS virtual core interfaces Yes VRRP Table 12 Gigabit Ethernet Modules GE HDE Line Module with GE 8 I O Modules GE 2 Line Module or GE HDE Line Module with GE 2 SFP I O formerly GE 2 APS I O or 2XGE APS I O GE FELineModuleswithGE I O Modules Protocol or Application Yes Yes Yes Accepts traffic destined for GRE tunnels or DVMRP IP in IP tunnels No No No APS MSP No No No ATM No No No ...

Page 91: ...ynamic interfaces Yes Yes Yes Ethernet raw mode encapsulation in Martini layer 2 circuits No No No F4 OAM and F5 OAM ATM administration No No No FDL facilities data link No Yes not yet fully qualified Yes Firewall No No No Frame Relay Yes including fast reconnection of PPPoE subscribers Yes including fast reconnection of PPPoE subscribers Yes including fast reconnection of PPPoE subscribers ICR Ye...

Page 92: ...Yes Yes LNS support peer side No No No Local loopback No No No MDL maintenance data link Yes not yet fully qualified Yes not yet fully qualified Yes Mobile IP home agent Yes Yes Yes MPLS No Yes Yes MPLS L2VPNs over the LAGs configuredbetweencustomer edge CE and provider edge PE devices No No No Multilink Frame Relay Yes with fragmentation and reassembly over MPL2TP on shared tunnel server port dyn...

Page 93: ...s Yes Yes PPPoE No No No Remote loopback Yes Yes Yes RIP Yes GRE tunnels only Yes GRE tunnels only Yes Subscriber interfaces static Yes Yes Yes Subscriber interfaces dynamic Yes Yes Yes S VLAN subinterface with an untaggedC VLANIDinMartini circuits Yes Yes Yes Transparent bridging Yes shared only Yes shared only No Tunnel server ports Yes Yes Yes Unified ISSU Yes Yes Yes VPLS network interfaces Ye...

Page 94: ...P IP in IP tunnels No No APS MSP No Yes ATM No No BERT No No BFD Yes Yes BGP Yes Yes BGP MPLS VPNs No Yes Bridged Ethernet No Yes Bridged IP No No Cisco HDLC Yes Yes DHCP external server Yes Yes DHCP local server Yes Yes DVMRP and GRE support access side No No DVMRP and GRE support server side Yes Yes Dynamic interfaces No Yes F4 OAM and F5 OAM ATM administration No No FDL facilities data link Yes...

Page 95: ...t No No IP reassembly for tunneled packets No No IPSec Yes Yes IPv6 Yes Yes IPv6 multicast Yes Yes IPv6 neighbor discovery Yes Yes IS IS Yes Yes J Flow Statistics No No L2TP IPSec Yes Yes LAC support access side Yes Yes LAC support peer side Yes Yes LNS support peer side No No Local loopback No No MDL maintenance data link Yes not yet fully qualified No Mobile IP home agent Yes Yes MPLS No No Mult...

Page 96: ...MA multipoint ATM Yes Yes OSPF Yes Yes Packet Mirroring No No Packet over SONET No Yes PPP Yes Yes PPPoE No No Remote loopback Yes Yes RIP Yes Yes over bridged Ethernet and IPoA Subscriber interfaces static Yes Yes over bridged Ethernet Subscriber interfaces dynamic Yes Yes Transparent bridging No No Tunnel server ports No No Unified ISSU Yes Yes VPLS network interfaces Yes Yes VPLS virtual core i...

Page 97: ...es BFD Yes Yes BGP Yes Yes BGP MPLS VPNs Yes Yes Bridged Ethernet Yes Yes Bridged IP No No Cisco HDLC Yes Yes DHCP external server Yes Yes DHCP local server Yes Yes DVMRP and GRE support access side No No DVMRP and GRE support server side Yes Yes Dynamic interfaces Yes Yes F4 OAM and F5 OAM ATM administration No No FDL facilities data link Yes Yes Firewall No No Frame Relay No No ICR No No IEEE 80...

Page 98: ...es Yes IPv6 neighbor discovery Yes Yes IS IS Yes Yes J Flow Statistics No No L2TP IPSec Yes Yes LAC support access side Yes Yes LAC support peer side Yes Yes LNS support peer side Yes No Local loopback No No MDL maintenance data link No No Mobile IP home agent Yes Yes MPLS No No Multilink Frame Relay Yes with fragmentation and reassembly Yes with fragmentation and reassembly Multilink PPP Yes Yes ...

Page 99: ...No No Tunnel server ports Yes only for non channelized APS IOAs when APS is not configured Yes only for non channelized APS IOAs when APS is not configured Unified ISSU Yes Yes VPLS network interfaces Yes Yes VPLS virtual core interfaces No No VRRP OCx STMx POS and OC48 Modules Table 15 OCx STMx POS and OC48 Modules OC48 Line Module with OC48 Frame APS I O Module OCx STMx POS Line Modules with OC1...

Page 100: ...uplink interfaces POS access interfaces not yet fully qualified DHCP external server Yes for POS access interfaces not yet fully qualified Yes for POS access interfaces not yet fully qualified Yes for POS access interfaces not yet fully qualified DHCP local server No No No DVMRP and GRE support access side Yes Yes Yes DVMRP and GRE support server side No No No Dynamic interfaces No No No F4 OAM an...

Page 101: ...es J Flow Statistics No No No L2TP IPSec No No No LAC support access side Yes Yes Yes LAC support peer side Yes Yes Yes LNS support peer side No No No Local loopback No No No MDL maintenance data link No No No Mobile IP home agent Yes Layer 2 over MPLS is not supported Yes Layer 2 over MPLS is not supported Yes MPLS No No No Multilink Frame Relay No No No Multilink PPP Yes Yes Yes Network Address ...

Page 102: ...nterfaces dynamic No No No Transparent bridging No No No Tunnel server ports No Yes Only for non channelized APS IOAs when APS is not configured Yes Only for non channelized APS IOAs when APS is not configured Unified ISSU No No No VPLS network interfaces Yes Yes Yes VPLS virtual core interfaces No No No VRRP Service Modules Table 16 Service Modules Service Line Module SM Protocol or Application N...

Page 103: ...erver ports DVMRP and GRE support server side No Dynamic interfaces No F4 OAM and F5 OAM ATM administration No FDL facilities data link Yes Firewall No Frame Relay No ICR No IEEE 802 3ad link aggregation No IEEE 802 3ah OAM link fault management Yes IP Yes IP multicast Yes IP reassembly for tunneled packets No IPSec Yes IPv6 Yes IPv6 multicast No IPv6 neighbor discovery Yes IS IS 103 Copyright 201...

Page 104: ... No Multilink Frame Relay Yes with fragmentation and reassembly dynamic only Multilink PPP Yes Network Address Translation NAT No NBMA multipoint ATM Yes OSPF Yes Packet Mirroring No Packet over SONET Yes dynamic only PPP No PPPoE No Remote loopback Yes RIP Yes GRE tunnels only Subscriber interfaces static Yes over GRE tunnels only Subscriber interfaces dynamic No Transparent bridging Yes dedicate...

Page 105: ... T3 12 I O Modules Protocol or Application Yes Yes Accepts traffic destined for GRE tunnels or DVMRP IP in IP tunnels No No APS MSP Yes No ATM point to point No Yes BERT No No BFD Yes Yes BGP Yes Yes BGP MPLS VPNs Yes No Bridged Ethernet Yes No Bridged IP No Yes Cisco HDLC Yes No DHCP external server Yes No DHCP local server No No DVMRP and GRE support access side Yes Yes DVMRP and GRE support ser...

Page 106: ... No No IEEE 802 3ad link aggregation No No IEEE 802 3ah OAM link fault management Yes Yes IP No No IP multicast No No IP reassembly for tunneled packets No No IPSec No No IPv6 No No IPv6 multicast No No IPv6 neighbor discovery Yes Yes IS IS Yes Yes J Flow Statistics No No L2TP IPSec Yes No LAC support access side Yes No LAC support peer side Yes No LNS support peer side No Yes Local loopback No Ye...

Page 107: ...ssembly Multilink PPP Yes Yes Network Address Translation NAT Yes No NBMA multipoint ATM Yes Yes OSPF Yes Yes Packet Mirroring No No Packet over SONET Yes Yes PPP Yes No PPPoE No Yes Remote loopback Yes Yes RIP Yes over bridged Ethernet and IPoA Yes Subscriber interfaces static Yes over bridged Ethernet Yes Subscriber interfaces dynamic Yes No Transparent bridging No No Tunnel server ports Yes No ...

Page 108: ...Copyright 2010 Juniper Networks Inc 108 ERX 11 3 x Module Guide ...

Page 109: ...s LED on a line module corresponds to the number of the port on the I O module Some line modules have more port status LEDs than the number of ports on the I O module In these cases only the LEDs for the corresponding ports on the I O modules are active For example an OCx STMx line module can pair with either an OC3 4 or an OC12 STM4 I O module Consequently the line module has four port status LED...

Page 110: ... LINK Ethernet line modules No Ethernet traffic on link Blinks when Ethernet traffic on link Green Ethernet ACTIVITY If the port is configured as DTE the LED goes out when either the DCE or the clock source becomes unavailable If the port is configured as DCE the LED goes out when the DTE becomes unavailable If the port is configured as DTE the LED lights when both the DCE and the clock source are...

Page 111: ...een Port status V 35 X 21 cable disconnected X 21 cable connected Green Port status X 21 DCE cable disconnected DCE cable connected Green Port status DCE DTE cable disconnected DTE cable connected Green Port status DTE Not in frame In frame Green Port status SYNC Other line modules No FERF present Far end receive failure FERF exists Yellow Port status YEL ALM In frame Loss of sync frame Red Port s...

Page 112: ...ine The standby SRP module monitors an activity signal from the primary SRP module to determine its state it does not shadow the operations of the primary SRP module If the standby SRP module detects that the primary SRP module is not active it reboots the system and takes control ERX7xx 14xx models only Copyright 2010 Juniper Networks Inc 112 ERX 11 3 x Module Guide ...

Page 113: ...Module LEDs Redundancy Status You can determine the redundancy state of line modules by examining the online and redundant status LEDs ERX7xx 14xx models only See Table 19 on page 114 113 Copyright 2010 Juniper Networks Inc Appendix B Module LEDs ...

Page 114: ...e State of the Line Module REDUNDANTLED ONLINE LED Module is booting or is an inactive primary line module Off Off Module is active but no standby module is available Off On Module is in standby state On Off Module is active and a standby module is available On On Copyright 2010 Juniper Networks Inc 114 ERX 11 3 x Module Guide ...

Page 115: ... Display Name Label Name SRP Modules ERX 5G2GEC2 SRP SRP 5GPlus SRP 5G ERX 10G2GEC2 SRP SRP 10G SRP 10G ERX 40G2GEC2 SRP SRP 40G SRP 40G Plus EX3 1GSRP MOD SRP SE10G SRP SE10G Line Modules CT3 12 F0 CT3 12 CT3 T3 F0 ERX UT3E3OCX MOD UT3f 12 COCX F3 COCX STMX F0 COC3 COC12 cOCx STMx F0 ERX O3O12A MOD OC3 OC12 ATM OCx STMx ATM ERX OCXA256M MOD OC3 OC12 DS3 ATM OCx STMx DS3 ATM ERX O3O12P MOD OC3 OC1...

Page 116: ...A OC12 MM 2P I O OC12 STM4 APS MULTI MODE ERX OC12SM A IOA OC12 SM 2P IR I O OC12 STM4 APS SINGLE MODE ERX OC3M APS IOA OC3 8 MM I O 4XOC3 APS I O MULTI MODE ERX OC3S APS IOA OC3 8 SM IR I O 4XOC3 APS I O SINGLE MODE ERX OC48ST16 IOA OC48 POS I O OC48 FRAME APS OC12 LH I O OC12 SM I O OC12 STM4 I O LONG HAUL OC12 MM I O OC12 MM I O OC12 STM4 I O MULTI MODE OC12 SM I O OC12 SM I O OC12 STM4 I O SIN...

Page 117: ...Label Name FE 8 I O FE 8 I O FE 8 I O ERX 2OC3GE IOA OC3 2A GE OC3 2 GE APS I O SFP ERX GIGESFP IOA GE SFP I O GE I O SFP ERX 2GE IOA GE 2 I O GE 2 SFP I O ERX 8GEHDE IOA GE 8 I O GE 8 I O 117 Copyright 2010 Juniper Networks Inc Appendix C Module Name Cross Reference Information ...

Page 118: ...Copyright 2010 Juniper Networks Inc 118 ERX 11 3 x Module Guide ...

Page 119: ... electrical and electronics manufacturers to provide mechanisms for the recycling and reuse of their products The RoHS Directive restricts the use of certain substances that are commonly found in electronic products today Restricted substances include heavy metals including lead and polybrominated materials The RoHS Directive with some exemptions applies to all electrical and electronic equipment ...

Page 120: ...rks account representative Products returned through our reclamation process are recycled recovered or disposed of in a responsible manner Our packaging is designed to be recycled and should be handled in accordance with your local recycling policies Copyright 2010 Juniper Networks Inc 120 ERX 11 3 x Module Guide ...

Page 121: ...Copyright 2010 Juniper Networks Inc ...

Page 122: ...Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks U S Patent Nos 5 473 599 5 905 725 5 909 440 6 192 051 6 333 650 6 359 479 6 406 312 6 429 706 6 459 579 6 493 347 6 538 518 6 538 899 6 552 918 6 567 902 6 578 186 and 6 590 785 E Series Broadband Services Routers ERX Module Guide Release 11 3 x Copyright 2010 ...

Reviews: