VessRAID 1740s, 1840s Product Manual
34
Express
When you choose the Express option, a set of characteristics and options
appears on the screen.
1.
Check the boxes to select any one or a combination of:
•
Redundancy
– The array will remain available if a physical drive fails
•
Capacity
– The greatest possible amount of data capacity
•
Performance
– The highest possible read/write speed
•
Spare Drive
– A hot spare drive
2.
In the Number of Logical Drives field, enter the number of logical drives you
want to make from this disk array.
The maximum possible number of logical drives appears to the right of this
field.
3.
From the Application Type menu, select an application that best describes
your intended use for this disk array:
•
File Server
•
Video Stream
•
Transaction Data
•
Transaction Log
•
Other
4.
Click the
Update
button.
Or check the Automatic Update box and updates will occur automatically.
The following parameters display:
•
Disk Arrays
– The number of physical drives in the disk array, their ID
numbers, configurable capacity, and the number of logical drives to be
created
•
Logical Drives
– The ID number of the logical drives, their RAID level,
capacity, and stripe size
•
Spare Drives
– The physical drive ID number of the dedicated hot spare
assigned to this disk array
If you have both Hard Disk Drives (HDD) and Solid State Drives (SSD),
separate disk arrays will be created for your HDDs and for your SSDs. Each
array will have the number of logical drives that you specified.
If you accept these parameters, proceed to the next step. If NOT, review and
modify your selections in the previous steps.
5.
When you are done, click the
Submit
button.
The new disk array appears in the Disk Array List on the Information tab.
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...