Chapter 9: Troubleshooting
281
You can set the VessRAID to migrate disk arrays under Non-Volatile Random
Access Memory (NVRAM), a much faster process because it writes data to the
memory in the controller. However, if a physical drive or the controller fails during
migration, the logical drives will go offline and you will lose data. See “Incomplete
Array” on page 279.
Because the setting for migration under NVRAM requires special access, most
users will not encounter this condition.
Physical Drive Fails during Transport
Transport is the action of moving the physical drives of a disk array:
•
To different slots in the same VessRAID enclosure
•
From one VessRAID enclosure to another
If a physical drive fails during a transport, or you do not move all of the physical
drives to their new locations, WebPAM PROe will display an incomplete array.
See “Incomplete Array” on page 279.
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...