VessRAID 1740s, 1840s Product Manual
138
Setting an Alias
An alias is optional. To set an Alias for a physical drive:
1.
From the Main Menu, highlight
Physical Drive Management
and press Enter.
2.
Highlight the physical drive of your choice and press Enter.
3.
Type an alias into the Alias field.
Maximum of 32 characters. Use letters, numbers, space between words
and underscore.
4.
Press Ctrl-A to save your settings.
Viewing Advanced Information
To view advanced information about the selected physical drive:
1.
From the Main Menu, highlight
Physical Drive Management
and press Enter.
2.
Highlight the physical drive of your choice and press Enter.
3.
Highlight
Advanced Information
and press Enter.
Viewing Physical Drive Statistics
To view the statistics for the selected physical drive:
1.
From the Main Menu, highlight
Physical Drive Management
and press Enter.
2.
Highlight the physical drive of your choice and press Enter.
3.
Highlight
Physical Drive Statistics
and press Enter.
Clearing Stale and PFA Conditions
The Clear Stale and Clear PFA functions only appear when those conditions exist
on the physical drive. To clear a Stale or PFA condition on a physical drive:
1.
From the Main Menu, highlight
Physical Drive Management
and press Enter.
2.
Highlight the physical drive of your choice and press Enter.
3.
Highlight
Clear Stale
or
Clear PFA
and press Enter.
If a physical drive is still online and shows a PFA error but “Clear PFA” does not
appear, use PDM to copy the data to a new physical drive. Go to Disk Array Info
and Settings.
If a physical drive is offline and shows a PFA error, rebuild the disk array. Go to
Disk Array Info and Settings. After rebuilding, the drive will show Stale. Run Clear
Stale then run Clear PFA.
If the physical drive with a PFA error is a spare, you must delete the drive as a
spare, then Clear PFA will be available.
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...