VessRAID 1740s, 1840s Product Manual
204
5.
Do one of the following actions:
•
Click the
Download from TFTP Server
option, then click the
Next
button.
•
From the Firmware Update tab dropdown menu, choose
Download from
TFTP Server
.
6.
Enter the hostname or IP address of your TFTP server in the field provided.
7.
Enter the port number of your TFTP server in the field provided (69 is the
default).
8.
Enter the filename of the Firmware Update file in the field provided.
9.
Click the
Submit
button.
10. When the download is completed, click the
Next
button.
A popup message appears warning you not to reboot the VessRAID during
the firmware update procedure.
11. In the popup message, click the
OK
button.
The update progress displays. Then a popup message appears to tell you to
reboot the VessRAID.
12. In the popup message, click the
OK
button.
13. Restart the VessRAID. See “Restarting the Subsystem” on page 205.
Updating Firmware from your PC
To update the firmware from your PC:
1.
Click the Subsystem
icon in Tree View.
2.
Click the Administrative Tools
icon.
3.
Click the Software Management
icon.
4.
Click the
Firmware Update
tab.
5.
Do one of the following actions:
•
Click the
Download Flash File from Local File through HTTP
option,
then click the
Next
button.
•
From the Firmware Update tab dropdown menu, choose
Download from
Local File
.
Note
After you click the
Submit
button, if WebPAM PROe displays this
message:
error transferring image
, you entered an incorrect file
name or an incorrect location. Check the information and try
again.
Summary of Contents for VessRAID 1740s
Page 1: ...VessRAID 1740s 1840s Product Manual Version 1 0 ...
Page 22: ...VessRAID 1740s 1840s Product Manual 8 ...
Page 52: ...VessRAID 1740s 1840s Product Manual 38 ...
Page 136: ...VessRAID 1740s 1840s Product Manual 122 ...
Page 145: ...Chapter 5 Management with the CLU 131 Figure 2 Controller Status LED Controller Status ...
Page 196: ...VessRAID 1740s 1840s Product Manual 182 ...