Troubleshooting
53
Symptom
Possible cause:
Remedy
Release but the nail is
not driven (lock-out).
The pusher spring is
defective.
Notify customer service
(see page 58).
The magazine is
fouled.
Clean the magazine.
The wrong nails are
loaded in the
magazine.
Empty the magazine
see page 41).
Fill magazine with
PREBENA nails (RK or
RKP) (see page 41).
The pneumatic tool
has not been
lubricated properly.
Add PREBENA special
nailer oil in the
compressed air
connection you are
using.
Release several times.
Insufficient operating
pressure.
Increase operating
pressure (see page 31).
The piston with the
driver does not return
to start position after
the driving process.
Notify customer service
(see page 58).
The release process
does not execute
completely.
Notify customer service
(see page 58).
The driver is bent
Notify customer service
(see page 58).
Release but the nail is
not driven (lock-out).
The tip of the driver is
visible in the nose of the
tool.
The connecting pin
between piston and
driver is broken.
Notify customer service
(see page 58).
If a malfunction cannot be resolved in spite of these instructions,