Preparing the pneumatic tool
21
If you use an unsuitable compressed air cartridge, and if both safety
valves are defective, then the pressure in this cartridge can exceed
the permissible operating pressure of the pneumatic tool. In this case
the pointer in the manometer for operating pressure will be in the red
area.
WARNING
Explosion hazard when exceeding the
maximum operating pressure.
In this case immediately disconnect the
compressed air cartridge from the
pneumatic tool.
If the pointer of the manometer on the cartridge connection is in the
red area, then the pressure available in the compressed air cartridge
is no longer sufficient to operate the pneumatic tool.
In this case replace the compressed air cartridge with a full
compressed air cartridge.
You can charge the compressed air cartridge with the PKT-
FILLMASTER 350 compressor that is available as an
accessory. Also you can exchange an empty cartridge when
purchasing a full cartridge from your dealer.