Troubleshooting
52
Symptom
Possible cause:
Remedy
Release is not possible. Insufficient operating
pressure.
Increase the operating
pressure of the
compressed air system
to 8.3 bar.
Then release several
times.
After release set the
desired operating
pressure (see page 31).
Change the compressed
air cartridge
(see page 19).
After a longer period of
storage the moving
parts are jammed with
lubricant.
Clean the pneumatic tool
and apply oil again
(see page 48).
Set the maximum
operating pressure.
Then release several
times.
After release set the
desired operating
pressure (see page 31).
Otherwise notify
customer service
(see page 48).
The lock-out safety
device is activated.
Fill magazine (see page
25).
When releasing, nails
fall out of the magazine.
The catch in the
pusher is defective
Notify customer service
(see page 58).