14 - 13
Control unit
Problem
Cause
Correction
no LED are lit
- supply voltage missing
check supply voltage
- supply voltage incorrect
connect properly
LED motor ready
(H1, H2, H3) is not lit
- signal input Enable not active
set input to active
up
motor is not rotating
- signal input current controller active
set input to inactive
and does not have a
holding torque
- motor connected incorrectly
connect properly
motor is not rotating
but does have a
- signal input pulse
correct timing and voltage level
holding torque
motor is rotating
- signal inputs pulse and direction
correct timing and voltage level
unevenly
- overload
check load conditions
- motor defective
replace motor
motor is rotating in
- motor phases connected the
connect motor
the wrong direction
wrong way round
phases properly
- signal input direction incorrectly
correct rotary direction
set
motor has too little
- motor phase current incorrectly
choose the correct phase
momentum
set
current
Additional problems
Summary of Contents for 3586-2/02
Page 4: ......
Page 10: ...1 5 Safety...
Page 22: ...Control elements 7 5...
Page 34: ...Preparation 9 7...
Page 88: ...11 48 Input...
Page 90: ......
Page 126: ...13 30 Adjustment...
Page 149: ...15 3 91 191 431 95 Version 21 05 02 Mains supply 230 V...
Page 150: ...15 4 Axle drives Version 21 05 02 91 191 431 95...
Page 151: ...15 5 91 191 431 95 Version 21 05 02 Sewing drive...
Page 152: ...15 6 Circuit diagram outputs Version 21 05 02 91 191 431 95...
Page 153: ...15 7 91 191 431 95 Version 21 05 02 Circuit diagram inputs...
Page 154: ...15 8 Circuit diagram A20 A26 A30 A50 Version 21 05 02 91 191 431 95...
Page 155: ...15 9 91 191 431 95 Version 21 05 02 Circuit diagram A21 A23...