13 - 25
Adjustment
75-020
13
.08.07
Zero point of the material take-over unit
Requirement
The lowered needle strip
1
should be parallel to the pressure bar
2
at a distance of
3 mm
.....
Fig. 13 - 23
●
Switch on the machine.
●
Select the ADJUST ZERO POINTS function on the graphics control panel.
●
Select the DEPTH function.
●
Move the needle strip
1
according to the
requirement
(number keys 1 and 2) and take
over the setting with
Enter
.
●
Insert disk (KONF.) and save the new zero point setting, see
Chapter 11.05 Functions in
the Input mode
under SERVICE, KONF./WRITE ZERO POINTS TO DISK.
0
5
4
2
Enter
3 mm
50-055a
2
1
3 mm
2
1