SINGLE MITRE SAW 50
ENG Rev 1
page 67
ANNEX
5
NOISE TESTS
The results of the measurements made are given in the following tables:
ACOUSTIC RADIATION PRESSURE LEVEL
LpAm
dB(A): 95,7
ACOUSTIC POWER LEVEL
LwA
dB(A): 111,8
ACOUSTIC PRESSURE LEVEL IN OPERATOR'S POSITION
LpA
dB(A): 94.3
The test conditions and instruments used are described in the TECHNICAL BOOKLET
corresponding to this manual.
Summary of Contents for Univer 50
Page 2: ......
Page 58: ...SINGLE MITRE SAW 50 ENG Rev 1 page 56...
Page 59: ...SINGLE MITRE SAW 50 ENG Rev 1 page 57 ANNEX 1 COMMERCIAL COMPONENTS...
Page 60: ...SINGLE MITRE SAW 50 ENG Rev 1 page 58 DRAWING OF COAXIAL UNIT...
Page 63: ...SINGLE MITRE SAW 50 ENG Rev 1 page 61 ANNEX 2 EXPLODED DRAWING OF MECHANICAL PARTS...
Page 64: ...SINGLE MITRE SAW 50 ENG Rev 1 page 62 DRAWINGS AND LISTS ARE TO BE UPDATED...