Hand-operated boom barriers Type GHS
Electrically operated boom barriers Type GES
Electro-hydraulically operated boom barrier Type GEHS
P
erimeter
P
rotection
G
ermany
G
mbH
Document: 2050274
Created: 11.04.2011
Version: a
Changed: 15.08.2013
Page 44 of 93
Original version
Subject to change
The electro-mechanical boom barriers of Types GES 2 - 4 have a one-sided barrier-boom
mount on the left or right. Place the barrier boom in the half shell mounted on the barrier
stand in such a way that the holes for the fastening screws align. Put the half shell that was
supplied loosely on top of the boom and fasten the screws.
The electrically operated boom barriers of Types GES 5 - 8 and the electro-hydraulically
operated boom barriers of Types GEHS 3
– 6 have a fork-shaped, central barrier-boom
mount. Push the barrier boom onto the tube of the boom mount and tighten the screws.
With the hand crank provided, the barrier can be closed.
Tighten the nuts once the alignment has been completed.
Figure 5.13
Electrical connection from the control
unit to the safety edge
in the case of GES 5 - 8