9
Item
Designation
A
Casing cover with quarter turn lock (4x)
B
EPP filter cover (2x)
C Filter
(2x)
D
Retaining clamps (4x)
E
Mounting bracket (4x)
F
Design filter cover (2x), Option
G
Heat exchanger box
H Control
system
I
Fan box (2x)
J Housing
Tab. 1: Main components CLIMOS
Type
plate
2.1.1
The type plate clearly identifies the product. The type plate is located on the side of the casing next to the
electrical connections. The information on the type plate is necessary for the safe use of the product and
in case of service-related questions. The type plate must be permanently attached to the product.
Fig 2: Type plate CLIMOS
Requirements on the assembly site
2.1.2
The heat recovery unit is suitable for being mounted in frost-free interior areas. The indoor-climate
ambient conditions must not permanently exceed 70 % r. F. at 22 °C.
Frost
protection
2.1.3
The CLIMOS is equipped with automatic frost protection which prevents that the heat exchanger freezes
at very low outside air temperatures. Depending on the set frost protection mode, the fans are temporarily
switched off when falling below the threshold values of the device intake air limit temperature. With regard
to the CLIMOS-series with integrated defroster, a PTC heater battery is activated when falling below the
threshold values of the device outside air limit temperature. However, if it is fallen below the threshold
values despite the heat quantity supplied by the integrated defroster, the fans are temporarily switched off
as well.
The automatic frost protection for monitoring the supply air temperature serves as freezing protection of
an optional downstream hydraulic heater battery and temporarily switches off the fans when falling below
the threshold values of the limit temperature for the supply air.
Joint operation with heat-producing appliances
2.1.4
In case of simultaneous operation with heat-producing appliances, e.g. chimneys, the corresponding
standards and regulations must be complied with by the qualified personnel. The joint operation of indoor
air-dependant heat-producing appliances and ventilation plants requires an appropriate safety device
(differential pressure switch) or a plant-specific measure, in the event that dangerous negative pressures
can be generated in the installation room of the heat-producing appliance during operation. The CLIMOS
is set up for the joint operation with heat-producing appliances.
Summary of Contents for CLIMOS F 200
Page 1: ...Version 2 0_06 2016 EN...
Page 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Page 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Page 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Page 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Page 65: ...65 Product fiche 4 5...