11
pressing another function key, the boost ventilation mode
can be cancelled at any time.
Key
Reset filter run-time
For cyclic filter checking, an operating hours counter is
integrated in the control. The key Reset filter run-time is
used for resetting the filter run-time.
…
Key combination
activation / deactivation
standby mode
By means of the standby function, the ventilation device is
switched to an energy-saving mode. By pressing the
–
key
several times until LED L1 goes off as well, the standby
mode is activated. This state is signalled by the periodic
blinking of the LED L8. When pressing the
+
key, the
standby mode is terminated and the fan speed 1 is set.
LED L1 is lit.
…
Key combination
configuration mode for
joint operation with
heat-producing
appliance
By pressing the key combination for at least 3 s, the extract
air mode is permanently deactivated. This state is signalled
by the LEDs L8+L11+L12, L8 and L12 being lit, L11
blinking 2x and then remaining off. This signalling is only
visible if the key combination is held down. An actuation of
the key Extract air mode in deactivated condition leads to
three short blinking of the LED L11, in order to signal the
deactivated condition. If the key combination is pressed
once again for at least 3 s, the key lock is deactivated. The
change is signalled by the LEDs L8+L11+L12, L8 and L12
being switched on, L11 blinking 2x and then remaining on.
This signalling is only visible if the key combination is held
down. In this way, the extract air mode is possible again.
The key Reset filter change must always be
pressed in the first place!
…
…
Key combination
configuration mode for
temperature threshold
summer ventilation
Keys for setting
The summer ventilation is with LED control
panel only be executed if it is enabled in the
factory settings.
By pressing the key combination for at least 3 s, the
configuration mode summer ventilation is activated and
the LEDs L8 and L10 are blinking.By means of the keys,
the temperature threshold for the summer ventilation can
be adjusted in dependency on the extract air temperature
between 21 °C (LED L1) and 27 °C (LED L7). After the
repeated actuation of the key combination for at least 3
sec, the setting is applied and the configuration mode for
temperature threshold summer ventilation is closed.
The key Reset filter change must always be
pressed in the first place!
…
…
Key combination
configuration mode
imbalance
Keys for balance setting
By pressing the key combination for at least 3 s, the
configuration mode imbalance is activated and the LEDs
L10 and L12 are blinking. By means of the keys for balance
setting, the balance of the fan speed which was active
during the activation of the configuration mode imbalance
can now be adjusted in steps of 5 %. The balance setting is
not carried out separately for each fan speed, but jointly for
groups of fan speeds.
The adjustable range is from -15 % (L1) to + 15 % (L7). In
centre position (L4), the supply and extract air fans run at
the same rotation speed. After having actuated the key
combination once again, the setting is accepted and the
configuration mode imbalance is terminated.
The key Reset filter change must always be
pressed in the first place!
1. Group
fan speeds <1+2>
2. Group
fan speeds <3+4+5>
3. Group
fan speeds <6+7>
Tab. 2: Operating functions of the LED control panel
Summary of Contents for CLIMOS F 200
Page 1: ...Version 2 0_06 2016 EN...
Page 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Page 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Page 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Page 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Page 65: ...65 Product fiche 4 5...