42
Terminal X1 master controller
Contact designation
X2.1
Digital input or output 1 (can be parameterized)
X2.2
Digital input or output 1 (GND)
X2.3
Digital input or output 2 (can be parameterized)
X2.4
Digital input or output 2 (GND)
Tab. 27: Terminal assignment DIO1 und DIO2
Operation without a control unit connected
3.4.7
When operating the ventilation device without control panel, the control operates according to the
operating mode set last.
The control panel may only be disconnected from the BUS in de-energised condition.
Disconnection during the operation results in a communication error!
Commissioning of the CLIMOS
3.5
Operational
readiness
3.5.1
Operational readiness is ensured if the requirements acc. to country-specific regulations
are met. For that purpose, cleanliness of the air duct material, the availability, correct
installation and operational readiness of the entire ventilation equipment provided for the
plant must be particularly ensured.
Check all safety-relevant parts and perform a functional test!
Adjusting the air volume flow
3.5.2
After having verified the operational readiness, the CLIMOS can be commissioned as follows. The
ventilation device is configured according to plant design for the total intake air volume flow with nominal
ventilation. This nominal air volume flow is parameterised in accordance with the characteristic curves of
the chart 1 Fig 43 (with control unit TFT touch panel) in the setup / submenu Fan speeds or according to
Tab. 29 (with control unit LED control panel).
3.5.2.1 Adjustment of the nominal air flow with TFT touch panel
For adjustment of the ventilation unit, the fan speed 2 (FS 2) for nominal air flow is set. The following
settings have to be made using the TFT touch panel:
Symbol
Designation
Explanation / actions
Button
Menu mode
Connect the first TFT touch panel
Buttons
Navigation
By touching the button Menu mode, you reach the main menus.
Button
Password
By touching the navigation buttons, select the main menu setup
and confirm with Enter.
Summary of Contents for CLIMOS F 200
Page 1: ...Version 2 0_06 2016 EN...
Page 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Page 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Page 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Page 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Page 65: ...65 Product fiche 4 5...