![Paul CLIMOS F 200 Original Operating Instructions Download Page 7](http://html1.mh-extra.com/html/paul/climos-f-200/climos-f-200_original-operating-instructions_4022625007.webp)
7
•
The instructions for regular checking and maintenance of the device must be strictly complied with;
•
Any modification of the CLIMOS is prohibited;
All enclosed documentation is a part of the product:
•
Read and observe the documentation;
•
Store the documentation in such a way that they are accessible at any time.
1.2.1.2 Control
unit
By means of the control units TFT touch panel or LED control panel, you configure and operate the
system from a central point. Both control units are exclusively suitable for indoor use.
Qualification of the target group
1.2.2
1.2.2.1 Operators
Operators must be instructed by qualified personnel:
•
Instruction on risks when handling electrical devices;
•
Instruction on the operation of the system;
•
Instruction on the maintenance of the CLIMOS;
•
Knowledge and observance of this manual with all notes on safety.
1.2.2.2 Qualified
personnel
Qualified personnel must possess the following qualifications:
•
Training in dealing with dangers and risks by the installation and operation of electric devices;
•
Training for the installation and commissioning of electrical equipment;
•
Knowledge and attention of the building, security and installation rules valid on the spot of the
appropriate municipalities, the waterworks and power plant and other official rules and directives;
•
Knowledge and observance of this document with all safety notices.
Only a recognized specialist is, unless otherwise specified in this manual, entitled the CLIMOS to install,
connect, bring into service and maintain.
Safety appliances and measures
1.2.3
•
Do not operate the CLIMOS without having connected air ducts with a minimum length of 900 mm;
•
The casing of the CLIMOS cannot be opened without tools;
•
Before opening the casing, the device must be disconnected from the power supply;
•
When working on electronic parts of the device, and antistatic wrist strap must be worn;
•
Replacement of spare parts and accessories only with the original of the manufacturer allowed.
Used
symbols
1.2.4
This manual contains the following advisory and safety symbols:
Special notice!
Caution, risk of:
- Damages to the device or the system
- Impairment of the device’s operation, if the instructions are not
strictly complied with.
Caution, risk of:
- Injury of the operator or the qualified personnel
Summary of Contents for CLIMOS F 200
Page 1: ...Version 2 0_06 2016 EN...
Page 57: ...57 Dimensional sketch 3 9 4 Fig 55 Dimension drawing HRU CLIMOS...
Page 58: ...58 Circuit diagram CLIMOS Basic series 3 9 5 Fig 56 Terminal assignment CLIMOS Basic...
Page 59: ...59 Circuit diagram CLIMOS Comfort series 3 9 6 Fig 57 Terminal assignment CLIMOS Comfort...
Page 60: ...60 Terminal scheme master controller 3 9 7 Fig 58 Terminal assignment Master Controller...
Page 65: ...65 Product fiche 4 5...